Thanks to special power and control electronics, absolute sensor technology and integrated position controller, the AG25 ultra-compact and powerful actuator is particularly well suited for format adjustments optimized for setup times. Due to the variety of available interface standards, quick and smooth integration into the existing controller is possible.
  • Small dimensions, high power density
  • easy mounting and commissioning
  • High flexibility, high protection class
  • stainless steel 14 mm diam. hollow shaft, robust housing

  • Brushless EC motor with a long service life
  • solid absolute sensor, magnetic sensing technology
  • integrated power and control electronics
  • Integrated Industrial-Ethernet-Fieldbus
  • Integrated positioning controller
  • M12 component mounting technology
  • Industry 4.0 ready
Technical data
Mechanical data
Shaft stainless steel
Housing glass-fiber reinforced plastic / zinc die-cast
Clamping ring stainless steel
Torque pin stainless steel (form A)
stainless steel (form B)
Nominal torque/rated speed 5 Nm at 50 rpm ±10 % (i = 98)
3 Nm at 75 rpm ±10 % (i = 66)
Operating mode intermittent duty S3: 25% DC, 10 min. (EN 60034-1)
Weight ~0.8 kg
Electrical data
Operating voltage 24 V DC ±10 % (reverse polarity protected, output stage)
24 V DC ±10 % (reverse polarity protected, control)
Current consumption 2.2 A ±10 % (at nominal torque/speed (output stage))
<150 mA (starting current >150 mA (control))
Power input ≤58 W (output stage)
≤3.6 W (Control)
Battery CR2477N, 3 V lithium, 950 mAh
Battery service life ~5 year(s) (depending on ambient conditions)
Parameter storage 106 cycles (also applies to calibration operations)
Digital inputs 17 … 30 V DC (typically 10 mA)
Status display 8 LEDs
Keys 2 internal keys, internal DIP switch
Switching outputs 24 V DC ±10 % (≤40 mA)
Bus connection EIP-EtherNet/IP
EPN-PROFINET
ECT-EtherCAT
EPL-POWERLINK
Type of connection 2x M12 plug connectors (A-coded) (4-pole, 1x pin; 8-pole, 1x pin)
2x M12 plug connectors (D-coded) (4-pole, 2x socket)
grounding via flat connector 6.3 mm
System data
Resolution 720 steps/revolution shaft
Repeat accuracy ±1 steps/revolution
Travel range ±1300 revolution(s) (i = 98)
±1980 revolution(s) (i = 66)
Failure rate 28.3 year(s) (at 60° C (MTBF) according to SN29500)
Approval UL 2011, CSA C22.2 No. 14-18, File No. E502992
Ambient conditions
Ambient temperature 0 … 45 °C
Storage temperature -20 … 60 °C
Relative humidity condensation inadmissible
EMC EN 61800-3, second environment (interference resistance / immission)
EN 61800-3, C2 (emitted interference / emission)
Protection category IP54, IP65 (EN 60529, only with mating connector  (degree of protection not tested by UL))
Shock resistance 500 m/s2, 11 ms (EN 60068-2-27)
Vibration resistance ≤100 m/s2, 5 … 150 Hz (EN 60068-2-6)