Ask an experienced consultant:
Level sensor wir 22mm diameter, for hydrostatic level measurement with capacitive ceramic measuring cell
Output signal RS485 Modbus-RTU
- Robust an precise ceramic cell
- Integrated temperature measurement possible
- Low energy consumption
The device Hydrocont HP4 is an electronic hydrostatic filling level transmitter for monitoring, control and continuous measurement of filling levels and temperatures.Due to its high accuracy and the digital adjustability by RS485 Modbus®-RTU the Hydrocont HP4 can be suited to a wide variety of applications.
The robust design and the high quality workmanship turns the device into a very high quality product, which even the most adverse environmental conditions cannot affect, whether the lowest temperatures when used outdoors, extreme shock and vibration stress or aggressive media.
A captive laser marking of the type label ensures the identifiability throughout the entire lifetime of the device. Obviously is the optional marking of a measurement point designation resp. TAG, a customer label or of a neutral type label, of course also per laser marking.
A LABS- resp. silicone-free version, a factory calibration with calibration certificate and a customer specific configuration resp. preset is also optionally available like a material test certificate EN10204 3.1 or a factory certifications for drink water suitability. Customer specific special versions can be realized short-term on request, e.g. special designs or other process materials.
Input Pressure | |
Nom. pressure PN relative | 0 bar … +0,1 bar up to 0 bar … +10 bar |
Characteristic deviation | ≤ ±0,05% FSO ≤ ±0,1% FSO ≤ ±0,2% FSO |
Temperature deviation | Tk Zero ≤ ±0,015% FSO/K Tk Zero ≤ ±0,75% FSO Tk Span ≤ ±0,015% FSO/K Tk Span ≤ ±0,5% FSO (at ≥ 0,4 bar) Tk Span ≤ ±0,8% FSO (at < 0,4 bar) |
Time behavior | T90 ≤ 2ms (td = 0s) |
Input Temperature | |
Sensor type | Pt1000 Class A |
Characteristic deviation | ≤ ±0,1K + 0,002 x [dt (25°C)] |
Time behavior | T90 ≤ 4s |
Output RS485 Modbus®-RTU | |
Interface | RS485, bidirectional Modbus®-RTU 9600 Baud (4800…38400 Baud) |
Time behavior | ton ≤ 250ms (td = 0s) |
Auxiliary power | |
Supply voltage Us (polarity protected) | 6 V…35 V DC |
Overvoltage protection | |
Coarse protection | 75 V / 10kA – wave 8/20µs all lines to PE |
Fine protection | 36V all lines to -L |
Environmental conditions | |
Environmental temperature | -20°C…+70°C |
Protection class | IP68 (EN/IEC 60529) |
Materials (Process wetted) | Ceramic Al2O3 CrNi-Steel FPM EPDM PE PUR |