Level limit switch Capcont LS
In order to select a replacement, contact our consultant.
Ask an experienced consultant:
For capacitive filling level supervision in liquids and solids
- For use in hygienic areas
- Switching point can be easily adjusted via the sliding sleeve
- Very compact
The level limit switch Capcont LS is suitable for limit value detection of also as dry run protection in liquids and viscous substances and also in powdery and fine granular substances. Like e.g. grain, flour, powdered milk, mixing food, cement, chalk or gypsum.
It can be used in electrically conductive as well as in non-conductive materials.
The device is certificated for the use as overflow protection acc. to WHG.
Capcont LS with integrated evaluation electronic is a compact filling level limit switch for supervision of filling levels.
Application
- liquids and solids within container or pipes
- also in explosive hazardous areas
- process temperatures from – 40°C to +140°C
- process pressures from –1 up to 10 bar.
- with metallic gasket and rod isolation in PEEK is especially suitable for the use in hygienic applications
Function
The device is a capacitive operating sensor for limit value detection. Electrode rod, filling material and container wall creates an electrical capacitor. The contact of the electrode rod with the filling material produces a variation in capacity. That is evaluated by the electronic and converted in a correspondent switching action.
The detection of a filling level signal is indicated at the plug side of the device by a yellow LED and converted into a switching command and output at the PNP switching output. This allows the drive of relays, contactors, magnetic vents, optical indicators, horns as well as of SPS inputs.
At a switching reaction, the voltage of the connection terminal 1 (+L) is output alternating by two contrary operated semiconductor switches at two connection terminals. The adjustment of the responsitivity of the device to the respective filling material is done by a potentiometer.
Capcont LS is mounted from the top side of the pressure container or of the pipe. Capcont LL is mounted from the top side or into the side wall of the pressure container or of the pipe.
Hilfsenergie | |
Spannungsversorgung | 10 V bis 35 V DC (verpolungsgeschützt) |
Stromaufnahme | ≤ 10mA Schaltausgang im Leerlauf |
Schaltausgang | |
Funktion | PNP-Transistorausgang, auf Kontakt +L |
Ausgangsstrom | ≤ 500mA strombegrenzt, kurzschlussfest |
Sperrstrom | ≤ 100µA |
Verzögerungszeit | ≤ 200ms ≥ 5Hz |
Schalthysterese | Abhängig vom Medium |
Empfindlichkeitsabgleich | Trimmer mehrgängig |
Werkstoffe | |
Elektrodenstabisolation | PTFE – Polytetrafluorethylen (Teflon®) (bei Variante LS) PEEK (bei Variante LL) |
Prozessanschluss | Stahl 1.4404 (AISI 316L) Stahl 1.4571 (AISI 316Ti) |
Gerätestecker M12x1 | Fassung:CrNi-Stahl Einsatz: PUR Kontakte vergoldet |
Dichtungen (prozessberührend) | FPM – Fluorelastomer (Viton®) EPDM – Etylen-Propylen-Dienmonomer |
Umgebungsbedingungen | |
Umgebungstemperatur | -40°C bis +100°C (Einschränkungen bei Ex-Ausführung) |
Prozesstemperatur | Capcont LS: -40°C bis +100°C (Einschränkungen bei Ex-Ausführung) Capcont LL: -40°C bis +140°C (Einschränkungen bei Ex-Ausführung) |
Prozessdruck | Capcont LS: -1bar bis +1bar Capcont LL: -1bar bis +10bar |
Schutzart | IP68 / 3mH20 für 1h DIN EN 60529 |