Precont® D40
PRODUCENT CODE: -
CATEGORY: Pressure sensors ACS - With digital display
Producer: ACS Control System
The product is available on request
At the moment, the product is not available in our warehouse.
After placing the order, we will notify you of the expected delivery date of the product.
At the moment, the product is not available in our warehouse.
After placing the order, we will notify you of the expected delivery date of the product.
Fast shipping
Free delivery
from 1000 PLN (net)
Free delivery
from 1000 PLN (net)
Do you have questions about the product?
Ask an experienced consultant:
Ask an experienced consultant:
Description
With flush, capacitive ceramic membrane for food applications
- To operate under extreme climatic conditions
- On-site programmable with bright LED
- Analouge and up to 4 switching points
The Precont® D40 is used in all fields of proceeding and process technique.
The excellent characteristics like pressure strength, high chemical resistance, corrosion protection and insensitivity against temperature shocks allows the use in the hardest applications for the measurement of gases, steams and liquids.
By the special contruction the device is especially suitable for the use in areas witht hight air humidity and at condensed water formation where conventional devices can not or can only be used with an expensive placed air compensation capillary.
Technical data
Auxiliary power supply | |
output signal 4…20mA (with display) | 16,5 V…45 V DC 16,5 V…30 V DC (with Ex variant) |
output signal 4…20mA (with display) | 12,5 V…45 V DC 12,5 V…30 V DC (with Ex variant) |
Output signal 0…10V | 16,5 V…45 V DC 16,5 V…30 V DC (with Ex variant) |
Supply current | |
2-wire 4…20mA | ≤ 22mA (PNP-switching outputs in neutral) |
3-wire 0…10V | ≤ 10mA (PNP-switching outputs in neutral) |
2xPNP-switching output | |
Function | PNP-switching on +Vs |
Output current | ≤ 250mA current limited short circuit protected |
Measurement accuracy | |
Characteristics deviation | ≤ ±0,1% / ±0,2% FS Measuring range 0,2bar/0,4bar/0,6bar: ±0,35% FS |
Long term drift | ≤ ±0,1% FS / year not cumulative |
Temperature deviation | ≤ ±0,30% FS / 10 K (Zero / Span) |
Materials | |
Membrane (medium contact) | Ceramics AL2O3 99,9% |
Process connection (medium contact) | Steel 1.4404/316L resp. 1.4571/316Ti |
Connection housing | CrNi-Steel |
Gaskets (medium contact) | FPM – fluoroelastomer (Viton®) EPDM – ethylene-propylene-diene monomer CR – chloroprene rubber (Neopren®) FFKM – perfluorelastomere (Kalrez®) NBR – nitrile-butadiene rubber |
Environmental conditions | |
Ambient temperature | -40°C…+85°C |
Process temperatures | – 40°C…+125°C |
Process pressure ranges | -1bar … +16bar |
Turn-Down | 4:1 |
Schutzart | IP65 / IP67 (EN/IEC 60529) |
Downloads