DCC 18 M 20/10 AIK-IBS
PRODUCENT CODE: 206291
CATEGORY: INA Analog
Producer: di-soric
636.30 PLN
(net)
7-14 days
The product is available on request
At the moment, the product is not available in our warehouse.
After placing the order, we will notify you of the expected delivery date of the product.
At the moment, the product is not available in our warehouse.
After placing the order, we will notify you of the expected delivery date of the product.
Fast shipping
Free delivery
from 1000 PLN (net)
Free delivery
from 1000 PLN (net)
Do you have questions about the product?
Ask an experienced consultant:
Ask an experienced consultant:
Description
The Analog series INA includes highly precise inductive proximity sensors which have an analog current and voltage output available. They are suited for measuring the distances of metallic parts in production or testing processes in which small changes in distance can reflect the quality of the process.
- Analog current output
- Analog voltage output
- Metal connector
- Integrated amplifier
- Short-circuit protection
- Inverse polarity protection
- Starting pulse suppression
Technical data
Electrical features | |
Service voltage | 15 … 30 V DC |
Internal power consumption | 12 mA |
Insulation voltage endurance | According to IEC 60947-5-2 (7.2.3.1) |
Mechanical features | |
Installation type | non-flush |
Thread | M18 x 1 |
Housing length | 63.4 mm |
Housing material | Brass (CuZn, nickel-plated) |
Material of sensor probe | PBT |
Certifications, approvals | |
Protection class | III, operation on protective low voltage |
General features | |
Operating principle | inductive |
Evaluation | analog |
Design | Thread |
Characteristics | extremely high operating distance |
Product series | INA Analog |
Output, input, interface | |
Analog output | 0 … 10 V (> 10 kΩ, unlinearized), 4 … 20 mA (< 0.5 kΩ, unlinearized) |
Detection range, measuring range, tolerance limits | |
Switching distance (SN) | 0 … 20 mm |
Resolution | 5.0 µm |
Standardized measuring plate | 60 x 60 x 1 mm |
Reproducibility | 0.05 mm (TA = constant), 0.3 mm (according to IEC 60947-5-2) |
Time behavior | |
Switching frequency | 250 Hz |
Ambient conditions | |
Shock/vibration load | IEC 60947-5-2 / 7.4 |
Ambient temperature during operation | -25 … +70 °C |
Protection type | IP 67 |
Electrical connection | |
Connection | Connector, M12, 4-pin, A-coded |
Accessories | |
Connection cable | VK … |
Downloads