Description
The modular and configurable MODSI safety system can monitor and control various safety equipment in parallel, including safety light curtains / grids, mechanical switches, floor mats, emergency stop switches and two-hand circuits, as well as combinations of these. Using expansion modules, MODSI can be individually adapted to the respective safety requirements.
- 4 safety relays with guided contacts
- 4 inputs to block start / restart and for external device monitoring (EDM)
- Outputs either as 4 independent outputs (security level 1 or 2) or 2 output pairs (security level 4) can be configured using MS-SD software
- 8 programmable digital signal outputs
- Connection to MS-1 master via MS-SC proprietary bus
- MS-SC plug connector included
Technical data
Electrical features | |
Service voltage | 19,2 … 28,8 V DC |
Mechanical features | |
Mounting | on DIN-rail in accordance with EN 50022-35 standard |
Housing dimensions | 99 x 22,5 x 114,5 mm |
Housing material | Plastic (PA) |
Material | Metal (Locking hook) |
Certifications, approvals | |
Characteristic variables | SIL 3 (IEC 61508), SILCL 3 (IEC 62061), PL e - Kat. 4 (EN ISO 13849-1) |
General features | |
Operating principle | Safety relay module |
Functional scope | |
Start / restart | 4 inputs (EDM) |
Scope of delivery | multi-language installation sheet, MS - Plug Connector MS-SC |
Output, input, interface | |
Signal outputs | pnp (8x), 100 mA / 24 V DC, programmable |
Communication | 5-way high-speed bus 5.0 |
Safety relay outputs | NO (4x) |
Display, operation | |
Display | LED (Output status) |
Ambient conditions | |
Ambient temperature during operation | -10 … +55 °C |
Protection type | IP 20 (Housing) / IP 2X (Terminal block) |
Electrical connection | |
Connection | removable terminal blocks, Screw contacts |