SLI4-1655
PRODUCENT CODE: 208941
CATEGORY: SL-4 Safety light curtains / grids type 4
Producer: di-soric
7-14 days
The product is available on request
At the moment, the product is not available in our warehouse.
After placing the order, we will notify you of the expected delivery date of the product.
At the moment, the product is not available in our warehouse.
After placing the order, we will notify you of the expected delivery date of the product.
Fast shipping
Free delivery
from 1000 PLN (net)
Free delivery
from 1000 PLN (net)
Do you have questions about the product?
Ask an experienced consultant:
Ask an experienced consultant:
Description
With safety level type 4, these safety light curtains / grids cover the highest safety level for finger, hand and body protection or in access control. The compact, slim devices can also be installed in confined space conditions. The master/slave variants as well as a version with integrated control function (EDM) are available as options.
- Highest safety level
- Resolution for body protection and presence control
- Protective range to profile end
- Integrated safety function - No external safety relay required
- Parameterization via connecting cable
- Selectable manual or automatic Start/Restart
- Feedback input for external relay monitoring (EDM)
- Unshielded connecting cables up to 100 m
- High protection type
Technical data
Electrical features | |
Service voltage | 19,2 … 28,8 V DC |
Inverse polarity protection | Yes |
Short-circuit protection | Yes |
Mechanical features | |
Total height (A) | 1.713 mm |
Mounting | T-groove (backside), / Holder SFB E 180 (optional) |
Housing material | Aluminum |
Material | Polycarbonate (Window) |
Certifications, approvals | |
Characteristic variables | Typ 4, Typ 4 (IEC/TS 61496-2), SIL 3 (IEC 61508), SILCL 3 (IEC 62061), PL e - Kat. 4 (EN ISO 13849-1) |
Protective function | Body protection |
Protection class | III, operation on protective low voltage |
General features | |
Model | built-in control functions (EDM) |
Functional scope | |
Start / restart | Automatic / manual (selectable) |
External device (relay) monitoring - EDM | Feedback input, selectable release |
Scope of delivery | Transmitter + receiver, one set of standard fixing brackets SA 6, CD-ROM containing the multi-language operating instructions, Quick installation guide |
Output, input, interface | |
Safety output | pnp (2x), 400 mA / 24 V DC |
Optical data | |
Light source | LED |
Color | Infrared |
Wavelength | 950 nm |
Detection range, measuring range, tolerance limits | |
Number of beams | 44 |
Protective field height (B) | 1.660 mm |
Range | 4.000 mm (Low range) / 12.000 mm (High range) |
Resolution | 50,0 mm |
Display, operation | |
Display | LED (Self-diagnosis and status of light barrier) |
Time behavior | |
Reaction time | 12 ms |
Ambient conditions | |
Ambient temperature during operation | -20 … +55 °C |
Protection type | IP 65 / IP 67 |
Electrical connection | |
Connection | Connector, M12, 5-pin (Transmitter) |
Connection 2 | Connector, M12, 8-pin (Receiver) |
Cable | unshielded connection cables max. 100 m |
Downloads