SR-M
PRODUCENT CODE: 209200
CATEGORY: SR Safety relay - Safety switching devices
Producer: di-soric
7-14 days
The product is available on request
At the moment, the product is not available in our warehouse.
After placing the order, we will notify you of the expected delivery date of the product.
At the moment, the product is not available in our warehouse.
After placing the order, we will notify you of the expected delivery date of the product.
Fast shipping
Free delivery
from 1000 PLN (net)
Free delivery
from 1000 PLN (net)
Do you have questions about the product?
Ask an experienced consultant:
Ask an experienced consultant:
Description
The safety relay / safety switching devices from di-soric make simple integration of individual safety sensors into occupational safety solutions possible. di-soric can optionally also deliver devices with integrated control function (External Device Monitoring - EDM) or with integrated muting function, to which additional external muting sensors can be connected.
- Usable for safety light curtains / grids with safety level type 2 and type 4
- Integrated muting function
- Additional safety functions
- Start / Restart Interlock
- Feedback input for EDM (for control of further external protections)
- LED indicators for status, muting and diagnostics
- Inverse polarity protection
Technical data
Electrical features | |
Service voltage | 19,2 … 28,8 V DC |
Inverse polarity protection | Yes |
Mechanical features | |
Mounting | on DIN-rail in accordance with EN 50022-35 standard |
Housing dimensions | 99 x 35 x 114,5 mm |
Certifications, approvals | |
Characteristic variables | Typ 4 (IEC/TS 61496-2), SILCL 3 (IEC 62061) PL e - Kat. 4 (EN ISO 13849-1) |
General features | |
Operating principle | Safety relay with muting function |
to be used for | all safety light curtains / grids |
Functional scope | |
Start / restart | Automatic / manual (selectable on terminal block), Interlock |
External device (relay) monitoring - EDM | Feedback input, selectable release |
Scope of delivery | Multi-language operating instructions |
Muting time exceedance | 30 sec. or infinite, selectable |
Override | 2 operating modes can be selected: manual and held or impulse command with automatic maintenance |
Output, input, interface | |
Two-channel inputs for safety light curtains / grids | 1 |
Status output | pnp (1x), 100 mA, 24 V DC |
Inputs for muting sensors | 2x, 24 V DC, pnp, dark switching |
Input for muting release | 24 V DC, pnp or relay (highly active) |
Muting lamp output | 24 V DC, 0.5 to 5 W |
Safety relay outputs | NO (2x), 2 A / 250 V AC |
Display, operation | |
Display | LED (Status input / output, inputs courageous sensors and fault diagnosis) |
Time behavior | |
Reaction time | < 20 ms |
Override time-out | 15 min |
Ambient conditions | |
Ambient temperature during operation | 0 … +55 °C |
Protection type | IP 20 (Housing) / IP 2X (Terminal block) |
Electrical connection | |
Connection | on terminal blocks |
Downloads