« Back
US 12 M 400 IU-B4

US 12 M 400 IU-B4

PRODUCENT CODE: 212884
CATEGORY: US-M12
Producer: di-soric
1232.35 PLN
(net)
7-14 days
The product is available on request
At the moment, the product is not available in our warehouse.
After placing the order, we will notify you of the expected delivery date of the product.
Fast shipping
Free delivery
from 1000 PLN (net)
Do you have questions about the product?
Ask an experienced consultant:
+48 577 575 085
rs@newtech.com.pl
Description
The US-M12 is the compact class of ultrasonic sensors in the M12 housing. Equipped with an IO-Link interface, the sensor can be operated to switch or to measure. The sensitivity can also be adjusted via auto-teach, so the sensor is thus operational within a few seconds.
  • IO-Link
  • Configurable as an ultrasonic sensor or barrier
  • 3 different teach modes
  • Working range adjustable
  • Analog output
  • Very narrow detection beam / small blind zone
  • Resistant to dirt
  • Small design
  • Robust metal housing
  • Protection class IP 67
Technical data
Electrical features
Service voltage 18 … 30 V DC
No-load current (max.) 40 mA (24 V DC)
Inverse polarity protection yes, except for the analog output PIN2
Short-circuit protection Yes
Insulation voltage endurance 500 V
Mechanical features
Housing dimensions M12 x 65 mm
Thread M12 x 1
Housing length 65 mm
Transmission exit axial
Assembly distance (sensor to sensor) 200 mm
Housing material Brass (CuZn, nickel-plated)
Material Epoxy resin, PUR (Transducer surface)
Weight 18 g
Certifications, approvals
Protection class III, operation on protective low voltage
General features
Operating principle Ultrasonic sensor, Ultrasonic barrier
Evaluation digital, analog (With IO-Link)
Design Thread
Characteristics IO-Link
Parallel operation possible Yes
Functional scope
Operation modes STANDARD, Master / slave function (synchronization or multiplex operation)
Scope of delivery Sensor, 2 x M12 nuts
Functions Teach, Out 1, IO-Link, multiplex, synchronization (PIN 4), Analog 0…10V / 4…20mA / 0… 20mA (Pin 2)
Output, input, interface
Switching output Push-pull, 150 mA, NO/NC, switchable
Max. switch current 150 mA
Voltage drop (max.) 2 V
Analog output 0 … 10 V, 4 … 20 mA (0 ... 20 mA IO-Link)
Interface IO-Link (V1.1, COM2 38.4 kBd, Smart Sensor Profile)
Load resistance > 10 KΩ (0 … 10 V) / < 400 Ω (4 … 20 mA / 0 ... 20 mA)
Detection range, measuring range, tolerance limits
Nominal switching distance (Sn) 400 mm
Range 40 … 400 mm
Adjustment range 40 … 400 mm (Teach in)
Resolution 1.0 mm (Adjusted measuring range/4095 (analog output))
Standardized measuring plate 200 x 200 mm
Switching hysteresis (max.) 2 … 20 mm (Adjustable by IO-Link)
Reproducibility < 1.5 mm
Linearity error < 0.4 %
Display, operation
Sensitivity adjustment Remote teach
Display LED 1x Green - Status, 1x yellow - Switching output
Time behavior
Measuring frequency 250 Hz
Ultrasonic frequency 300 kHz
Switching frequency 10 Hz
Readiness delay (max.) 300 ms
Ambient conditions
Shock/vibration load 30 g, 11 ms / 10 … 55 Hz, 1.0 mm
Ambient temperature during operation -25 … +70 °C
Temperature drift 0.2 %/K (uncompensated)
Temperature drift < 1 %/Sn (compensated)
Protection type IP 67
Electrical connection
Connection Connector, M12, 4-pin
Accessories
Connection cable VKHM … /4