Description
  • IO-Link
  • Configurable as an ultrasonic sensor or barrier
  • 3 different teach modes
  • Working range adjustable
  • Very narrow detection beam / small blind zone
  • Switching functions: Closer/opener, window function teachable
  • Resistant to dirt
  • Small design
  • Robust metal housing
  • Protection class IP 67
Technical data
Electrical features
Service voltage 18 … 30 V DC
No-load current (max.) 40 mA (24 V DC)
Inverse polarity protection yes, except for the analog output PIN2
Short-circuit protection Yes
Insulation voltage endurance 500 V
Mechanical features
Housing dimensions M18 x 55 mm
Thread M18 x 1
Housing length 55 mm
Transmission exit axial
Assembly distance (sensor to sensor) 700 mm
Housing material Brass (nickel-plated)
Material Epoxy resin, PUR (Transducer surface)
Weight 30 g
Certifications, approvals
Protection class III, operation on protective low voltage
General features
Operating principle Ultrasonic sensor, Ultrasonic barrier
Evaluation digital, analog
Design Thread
Characteristics IO-Link
Parallel operation possible Yes
Functional scope
Operation modes Master / slave function (synchronization or multiplex operation)
Scope of delivery Sensor, 2 x M18 nuts
Output, input, interface
Switching output Push-pull, 150 mA, NO/NC, switchable
Max. switch current 150 mA
Voltage drop (max.) 2 V
Analog output 0 … 10 V, 4 … 20 mA (0 ... 20 mA IO-Link)
Interface IO-Link (V1.1, COM2 (38.4kBd) Smart Sensor Profile)
Load resistance > 10 KΩ (0 … 10 V) / < 400 Ω (4 … 20 mA / 0 ... 20 mA)
Detection range, measuring range, tolerance limits
Nominal switching distance (Sn) 1500 mm
Range 150 … 1500 mm
Adjustment range 150 … 1500 mm (Teach in)
Resolution 1.0 mm (Adjusted measuring range/4095 (analog output))
Standardized measuring plate 200 x 200 mm
Switching hysteresis (max.) 6 mm (Adjustable up to 20 mm via IO-Link)
Reproducibility < 1 mm
Linearity error < 0.5 %
Display, operation
Sensitivity adjustment Remote teach
Display LED 1x Green - Status, 1x yellow - Switching output
Time behavior
Measuring frequency 100 Hz
Ultrasonic frequency 200 kHz
Switching frequency < 5 Hz
Readiness delay (max.) 300 ms
Ambient conditions
Shock/vibration load 30 g, 11 ms / 10 … 55 Hz, 1.0 mm
Ambient temperature during operation -25 … +70 °C
Temperature drift 0.2 %/K (compensated)
Temperature drift < 1 %/Sn (compensated)
Protection type IP 67
Electrical connection
Connection Connector, M12, 4-pin
Accessories
Connection cable VKHM … /4