Description
The US-Q12 is the compact class in cubic form and with a small mounting depth. Equipped with an IO-Link interface, the sensor can be operated to switch or to measure. Its area of application is short distances, and the sensitivity is adjusted simply via auto-teach, potentiometer or IO-Link.
- IO-Link
- Configurable as an ultrasonic sensor or barrier
- 3 different teach modes
- Working range adjustable
- Very narrow detection beam / small blind zone
- Switching functions: Closer/opener, window function teachable
- Resistant to dirt
- Small design
- Robust metal housing
- Protection class IP 67
Technical data
Electrical features | |
Service voltage | 18 … 30 V DC |
No-load current (max.) | 40 mA (24 V DC) |
Inverse polarity protection | yes, except for the analog output PIN2 |
Short-circuit protection | Yes |
Insulation voltage endurance | 500 V |
Mechanical features | |
Housing dimensions | 12 x 12 x 75 mm |
Housing length | 75 mm |
Housing height | 12 mm |
Housing width | 12 mm |
Transmission exit | radial |
Assembly distance (sensor to sensor) | 60 mm |
Housing material | Aluminum (Black, Anodized) |
Material | Epoxy resin, PUR (Transducer surface) |
Certifications, approvals | |
Protection class | III, operation on protective low voltage |
General features | |
Operating principle | Ultrasonic sensor, Ultrasonic sensor |
Evaluation | digital, analog (With IO-Link) |
Design | Cuboid design |
Characteristics | IO-Link |
Parallel operation possible | Yes |
Functional scope | |
Operation modes | STANDARD, Master / slave function (synchronization or multiplex operation) |
Functions | Teach, Out 1, IO-Link, multiplex, synchronization (PIN 4), Analog 0…10V / 4…20mA / 0… 20mA (Pin 2) |
Output, input, interface | |
Switching output | Push-pull, 150 mA, NO/NC, switchable |
Max. switch current | 150 mA |
Voltage drop (max.) | 2 V |
Analog output | 0 … 10 V, 4 … 20 mA |
Interface | IO-Link (V1.1, COM2 38.4 kBd, Smart Sensor Profile) |
Load resistance | > 10 KΩ (0 … 10 V) / < 400 Ω (4 … 20 mA / 0 ... 20 mA) |
Detection range, measuring range, tolerance limits | |
Nominal switching distance (Sn) | 200 mm |
Range | 20 … 200 mm (adjustable) |
Adjustment range | 20 … 200 mm (Teach in) |
Resolution | 1.0 mm (Adjusted measuring range/4095 (analog output)) |
Standardized measuring plate | 100 x 100 mm |
Switching hysteresis (max.) | 2 … 20 mm (Adjustable by IO-Link) |
Reproducibility | < 0.5 mm |
Linearity error | ± 0.4 % |
Display, operation | |
Sensitivity adjustment | Remote teach |
Display | LED 1x yellow - Switching output |
Time behavior | |
Measuring frequency | 400 Hz |
Ultrasonic frequency | 400 kHz |
Switching frequency | 20 Hz |
Readiness delay (max.) | 300 ms |
Ambient conditions | |
Shock/vibration load | 30 g, 11 ms / 10 … 55 Hz, 1.0 mm |
Ambient temperature during operation | -25 … +70 °C |
Temperature drift | 0.2 %/K (uncompensated) |
Temperature drift | < 1 %/Sn (compensated) |
Protection type | IP 67 |
Electrical connection | |
Connection | Connector, M8, 4-pin |
Accessories | |
Connection cable | TK … /4 |