« Back
IM002A - Inductive sensor

IM002A - Inductive sensor

PRODUCENT CODE: IM002A
CATEGORY: Inductive sensors ifm - Use in hazardous areas
Producer: ifm electronic
844.28 PLN
(net)
7-14 days
The product is available on request
At the moment, the product is not available in our warehouse.
After placing the order, we will notify you of the expected delivery date of the product.
Fast shipping
Free delivery
from 1000 PLN (net)
Do you have questions about the product?
Ask an experienced consultant:
+48 32 237 61 98 w. 101
bn@newtech.com.pl
Description
IME2040-FBOA/3D
  • For applications in hazardous areas
  • With combined AC/DC output and two-wire technology
  • Output function normally open / normally closed programmable
  • Robust housing for use in harsh industrial environments
  • Five positions of the sensing face selectable
Technical data
Product characteristics
Output function normally open / normally closed; (selectable)
Sensing range [mm] 40
Housing rectangular
Dimensions [mm] 40 x 40 x 105
Electrical data
Operating voltage [V] 20...250 AC/DC
Protection class II
Reverse polarity protection no
Outputs
Output function normally open / normally closed; (selectable)
Max. voltage drop switching output DC [V] 6
Max. voltage drop switching output AC [V] 6.5
Minimum load current [mA] 5
Max. leakage current [mA] 2.5 (250 V AC) / 1.3 (130 V AC) / 0.8 (24 V DC)
Permanent current rating of switching output AC [mA] 150
Permanent current rating of switching output DC [mA] 100
Short-time current rating of switching output [mA] 2200; (20 ms / 0,5 Hz)
Switching frequency AC [Hz] 10
Switching frequency DC [Hz] 10
Notes on switching frequency [Hz]
only for resistive loads; 2 Hz for utilisation category AC-140
Short-circuit proof no
Overload protection no
Detection zone
Sensing range [mm] 40
Real sensing range Sr [mm] 40 ± 10 %
Operating distance [mm] 0...32.4
Accuracy / deviations
Correction factor steel: 1 / stainless steel: 0.7 / brass: 0.4 / aluminium: 0.3 / copper: 0.2
Hysteresis [% of Sr] 1...20
Switch point drift [% of Sr] -10...10
Operating conditions
Ambient temperature [°C] -20...60
Protection IP 65; IP 67
Tests / approvals
ATEX marking II 3D Ex tc IIIC T95°C Dc X
EMC
EN 60947-5-2
MTTF [years] 554
Mechanical data
Weight [g] 253
Housing rectangular
Mounting non-flush mountable
Dimensions [mm] 40 x 40 x 105
Materials PC; PA; stainless steel
Displays / operating elements
Display
switching status 1 x LED, yellow
Electrical connection
Required protection miniature fuse to IEC60127-2 sheet 1; ≤ 2 A; fast acting; Place the fuse outside the hazardous area.
Remarks
Remarks
Recommendation: Check the safe functioning of the unit after a short circuit.
5 positions of the active zone possible
Pack quantity 1 pcs.
Electrical connection
Connection terminals: 0.34...2.5 mm²; Cable sheath: Ø 5...9 mm