NT5001 - Induktiver NAMUR-Sensor
PRODUCENT CODE: NT5001
CATEGORY: Inductive sensors ifm - Use in hazardous areas
Producer: ifm electronic
155.84 PLN
(net)
7-14 days
The product is available on request
At the moment, the product is not available in our warehouse.
After placing the order, we will notify you of the expected delivery date of the product.
At the moment, the product is not available in our warehouse.
After placing the order, we will notify you of the expected delivery date of the product.
Fast shipping
Free delivery
from 1000 PLN (net)
Free delivery
from 1000 PLN (net)
Do you have questions about the product?
Ask an experienced consultant:
Ask an experienced consultant:
Description
ITA2001-N/1D/1G
- For applications in hazardous areas
- For connection to intrinsically safe circuits
- Particularly short housing for use where space is restricted
- Very high switching frequency
- Robust metal housing for use in harsh industrial environments
Technical data
Product characteristics | |||
Electrical design | NAMUR | ||
Output function | normally closed | ||
Sensing range [mm] | 1 | ||
Housing | cylindrical | ||
Dimensions [mm] | Ø 6.5 / L = 30 | ||
Electrical data | |||
Connection to switching amplifiers | yes | ||
Switching amplifiers | connection to certified intrinsically safe circuits with the max. values: U = 15 V / I = 50 mA / P = 120 mW | ||
Nominal voltage DC [V] | 8.2; (1kΩ) | ||
Supply voltage DC [V] | 7.5...30; (when used outside the hazardous area) | ||
Current consumption [mA] | < 1; (disabled; conductive: &rt; 2,1) | ||
Protection class | III | ||
Outputs | |||
Electrical design | NAMUR | ||
Output function | normally closed | ||
Permanent current rating of switching output DC [mA] | 30; (when used outside the hazardous area) | ||
Switching frequency DC [Hz] | 2000 | ||
Detection zone | |||
Sensing range [mm] | 1 | ||
Real sensing range Sr [mm] | 1 ± 10 % | ||
Accuracy / deviations | |||
Correction factor | steel: 1 / stainless steel: 0.7 / brass: 0.5 / aluminium: 0.4 / copper: 0.3 | ||
Hysteresis [% of Sr] | 1...15 | ||
Switch point drift [% of Sr] | -10...10 | ||
Operating conditions | |||
Ambient temperature [°C] | -20...80 | ||
Protection | IP 67 | ||
Tests / approvals | |||
Approval | PTB 01 ATEX 2191; BVS 04 ATEX E 153 X; IECEX BVS 06.0003X | ||
ATEX marking | II 1G Ex ia IIC T6 Ga Ta -20...70°C | ||
EMC |
|
||
Shock/vibration resistance | 30 g (11 ms) / 10-55 Hz (1 mm) | ||
MTTF [years] | 4816 | ||
Safety classification | |||
Max. internal capacitance [nF] | 80 | ||
Max. internal inductance [µH] | 70 | ||
Mechanical data | |||
Weight [g] | 116 | ||
Housing | cylindrical | ||
Mounting | flush mountable | ||
Dimensions [mm] | Ø 6.5 / L = 30 | ||
Materials | brass special coating; sensing face: PBT | ||
Remarks | |||
Pack quantity | 1 pcs. | ||
Electrical connection | |||
Connection | Cable: 2 m, PVC; 2 x 0.14 mm² |