OGD251 - Photoelectric distance sensor
PRODUCENT CODE: OGD251
CATEGORY: Type M18 Cube in metal housing
Producer: ifm electronic
7-14 days
The product is available on request
At the moment, the product is not available in our warehouse.
After placing the order, we will notify you of the expected delivery date of the product.
At the moment, the product is not available in our warehouse.
After placing the order, we will notify you of the expected delivery date of the product.
Fast shipping
Free delivery
from 1000 PLN (net)
Free delivery
from 1000 PLN (net)
Do you have questions about the product?
Ask an experienced consultant:
Ask an experienced consultant:
Description
OGDLF8KG/IO-LINK/US
- Small compact design with standard M18 thread and PMD time-of-flight technology
- Measurement to the nearest millimetre and monitoring of distances in the running process
- Colour-independent range
- Simultaneous output of distance value and reflectivity for increased process reliability
- Convenient operation via buttons or parameter setting via IO-Link
Technical data
Product characteristics | |||||||||||
Type of light | red light | ||||||||||
Laser protection class | 1 | ||||||||||
Housing | rectangular with M18 thread | ||||||||||
Electrical data | |||||||||||
Operating voltage [V] | 18...30 DC; ("supply class 2" to cULus) | ||||||||||
Current consumption [mA] | 45; (24 V) | ||||||||||
Protection class | III | ||||||||||
Reverse polarity protection | yes | ||||||||||
Type of light | red light | ||||||||||
Wave length [nm] | 650 | ||||||||||
Inputs / outputs | |||||||||||
Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 | ||||||||||
Inputs | |||||||||||
Inputs | Laser On/ Off | ||||||||||
Outputs | |||||||||||
Total number of outputs | 2 | ||||||||||
Electrical design | PNP/NPN; (parameterisable) | ||||||||||
Number of digital outputs | 2 | ||||||||||
Output function | 2 x normally open / normally closed; (parameterisable) | ||||||||||
Max. current load per output [mA] | 100 | ||||||||||
Number of analogue outputs | 1 | ||||||||||
Analogue current output [mA] | 4...20; (IEC 61131-2) | ||||||||||
Max. load [Ω] | 250 | ||||||||||
Analogue voltage output [V] | 0...10; (IEC 61131-2) | ||||||||||
Min. load resistance [Ω] | 5000 | ||||||||||
Short-circuit protection | yes | ||||||||||
Type of short-circuit protection | pulsed | ||||||||||
Overload protection | yes | ||||||||||
Switching frequency DC [Hz] | 20 | ||||||||||
Switching frequency DC [Hz] | 40 | ||||||||||
Switching frequency DC [Hz] | 60 | ||||||||||
Detection zone | |||||||||||
Max. light spot diameter [mm] | 5 | ||||||||||
Light spot dimensions refer to | at maximum range | ||||||||||
Background suppression [m] | < 20 | ||||||||||
Measuring/setting range | |||||||||||
Setting range object reflectivity [%] | 6...900; (reflectivity; 6 % black paper; 100 % white paper) | ||||||||||
Measuring range [m] | 0.05...2 | ||||||||||
Sampling rate [Hz] | 60 | ||||||||||
Measuring range [m] | 0.05...2 | ||||||||||
Sampling rate [Hz] | 120 | ||||||||||
Measuring range [m] | 0.05...1 | ||||||||||
Sampling rate [Hz] | 180 | ||||||||||
Software / programming | |||||||||||
Parameter setting options | Distance / reflectivity; hysteresis / window; Sensitivität; current/voltage output; Sequence modulation to avoid mutual interference by similar sensors | ||||||||||
Interfaces | |||||||||||
Communication interface | IO-Link | ||||||||||
Transmission type | COM2 (38,4 kBaud) | ||||||||||
IO-Link revision | 1.1.3 | ||||||||||
SDCI standard | IEC 61131-9 | ||||||||||
Profiles | Smart Sensor: Sensor Identification; Binary Data Channel; Process Value; Sensor Diagnosis | ||||||||||
SIO mode | yes | ||||||||||
Required master port type | A | ||||||||||
Min. process cycle time [ms] | 5 | ||||||||||
IO-Link process data (cyclical) |
|
||||||||||
IO-Link functions (acyclical) | application specific tag; operating hours counter; switching cycles counter | ||||||||||
Supported DeviceIDs |
|
||||||||||
Note |
|
||||||||||
Operating conditions | |||||||||||
Ambient temperature [°C] | -25...50 | ||||||||||
Note on ambient temperature |
|
||||||||||
Storage temperature [°C] | -30...80 | ||||||||||
Protection | IP 65; IP 67 | ||||||||||
Tests / approvals | |||||||||||
EMC |
|
||||||||||
Laser protection class | 1 | ||||||||||
Notes on laser protection |
|
||||||||||
MTTF [years] | 258 | ||||||||||
UL approval |
|
||||||||||
Mechanical data | |||||||||||
Weight [g] | 53.4 | ||||||||||
Housing | rectangular with M18 thread | ||||||||||
Dimensions [mm] | 61.7 x 22.5 x 45.2 | ||||||||||
Thread designation | M18 x 1 | ||||||||||
Materials | housing: PPSU; ABS; PMMA; PBT / PC; EPDM; front pane: PMMA | ||||||||||
Lens alignment | side lens | ||||||||||
Displays / operating elements | |||||||||||
Display |
|
||||||||||
Operating elements |
|
||||||||||
Accessories | |||||||||||
Items supplied |
|
||||||||||
Remarks | |||||||||||
Pack quantity | 1 pcs. | ||||||||||
Electrical connection | |||||||||||
Connection | Connector: 1 x M12; coding: A | ||||||||||
Hysteresis graph for distance measurement / operating mode: FINE |
|
||||||||||
Hysteresis graph for distance measurement / operating mode: STD |
|
||||||||||
Hysteresis graph for distance measurement / operating mode: FAST |
|
||||||||||
hysteresis curve for object reflectivity | |||||||||||
Other data |
Downloads