« Back
OGD550 - Photoelectric distance sensor

OGD550 - Photoelectric distance sensor

PRODUCENT CODE: OGD550
CATEGORY: Type M18 Cube in metal housing
Producer: ifm electronic
7-14 days
The product is available on request
At the moment, the product is not available in our warehouse.
After placing the order, we will notify you of the expected delivery date of the product.
Fast shipping
Free delivery
from 1000 PLN (net)
Do you have questions about the product?
Ask an experienced consultant:
+48 32 237 61 98 w. 101
bn@newtech.com.pl
Description
OGDLFCKG/IO-LINK/US
  • Small compact design with standard M18 thread and PMD time-of-flight technology
  • Measurement to the nearest millimetre and monitoring of distances in the running process
  • Colour-independent range
  • Simultaneous output of distance value and reflectivity for increased process reliability
  • Convenient operation via buttons or parameter setting via IO-Link
Technical data
Product characteristics
Type of light red light
Laser protection class 1
Housing rectangular with M18 thread
Electrical data
Operating voltage [V] 10...30 DC; ("supply class 2" to cULus)
Current consumption [mA] 45; (24 V)
Protection class III
Reverse polarity protection yes
Type of light red light
Wave length [nm] 650
Inputs
Inputs Laser On/ Off
Outputs
Electrical design PNP/NPN; (parameterisable)
Output function 2 x normally open / normally closed; (parameterisable)
Max. current load per output [mA] 100
Short-circuit protection yes
Type of short-circuit protection pulsed
Overload protection yes
Switching frequency DC [Hz] 20
Switching frequency DC [Hz] 40
Switching frequency DC [Hz] 60
Detection zone
Max. light spot diameter [mm] 5
Light spot dimensions refer to at maximum range
Background suppression [m] < 20
Measuring/setting range
Setting range object reflectivity [%] 6...900; (reflectivity; 6 % black paper; 100 % white paper)
Measuring range [m] 0.05...2
Sampling rate [Hz] 60
Measuring range [m] 0.05...2
Sampling rate [Hz] 120
Measuring range [m] 0.05...1
Sampling rate [Hz] 180
Software / programming
Parameter setting options Distance / reflectivity; hysteresis / window; Sensitivität; current/voltage output; Sequence modulation to avoid mutual interference by similar sensors
Interfaces
Communication interface IO-Link
Transmission type COM2 (38,4 kBaud)
IO-Link revision 1.1.3
SDCI standard IEC 61131-9
Profiles Smart Sensor: Sensor Identification; Binary Data Channel; Process Value; Sensor Diagnosis
SIO mode yes
Required master port type A
Min. process cycle time [ms] 5
IO-Link process data (cyclical)
function bit length
process value 2 x 16
device status 4
binary switching information 2
IO-Link functions (acyclical) application specific tag; operating hours counter; switching cycles counter
Supported DeviceIDs
Type of operation DeviceID
default 1581
Note
For further information please see the IODD PDF file under "Downloads"
Operating conditions
Ambient temperature [°C] -25...60
Note on ambient temperature
In ambient temperatures < -10 °C a warm-up time is necessary.
Laser is off.
Storage temperature [°C] -30...80
Protection IP 65; IP 67
Tests / approvals
EMC
EN 60947-5-2
Laser protection class 1
Notes on laser protection
Caution: laser light
laser class: 1
EN / IEC60825-1:2007
EN / IEC60825-1:2014
Complies with 21 CFR 1040 except for deviations pursuant to Laser Notice No. 50, dated June 2007.
MTTF [years] 319
UL approval
Ta -25...60 °C
Enclosure type Type 1
power supply Class 2
File number UL E174191
Mechanical data
Weight [g] 133.13
Housing rectangular with M18 thread
Dimensions [mm] 61.7 x 22.5 x 45.2
Thread designation M18 x 1
Materials housing: stainless steel (1.4404 / 316L); PPSU; ABS; PMMA; PBT / PC; EPDM; front pane: PMMA
Lens alignment side lens
Displays / operating elements
Display
switching status 2 x LED, yellow
1 x alphanumeric display, 4-digit
Operating elements
3 pushbutton
Accessories
Items supplied
lock nuts: 2
Remarks
Pack quantity 1 pcs.
Electrical connection
Connection Connector: 1 x M12; coding: A
Hysteresis graph for distance measurement / operating mode: FINE
1: Background any (6...90 % remission)
2: background white (90 % remission)
Hysteresis graph for distance measurement / operating mode: STD
1: Background any (6...90 % remission)
2: background white (90 % remission)
Hysteresis graph for distance measurement / operating mode: FAST
1: Background any (6...90 % remission)
2: background white (90 % remission)
hysteresis curve for object reflectivity
Other data