« Back
PG2458 - Pressure sensor with analogue display

PG2458 - Pressure sensor with analogue display

PRODUCENT CODE: PG2458
CATEGORY: Electronic contact manometers with analogue display
Producer: ifm electronic
2261.87 PLN
(net)
7-14 days
The product is available on request
At the moment, the product is not available in our warehouse.
After placing the order, we will notify you of the expected delivery date of the product.
Fast shipping
Free delivery
from 1000 PLN (net)
Do you have questions about the product?
Ask an experienced consultant:
+48 32 237 61 98 w. 101
bn@newtech.com.pl
Description
PG-,25BREB12-MFRKG/US/ /P
  • Analogue display, pressure switch and transmitter in one unit
  • Excellent readability also over a long distance
  • Rotatable display with LED bar graph for switch point indication
  • Programmable switching output and scalable analogue output
  • Robust stainless steel housing for use in harsh industrial environments
Technical data
Product characteristics
Number of inputs and outputs Number of digital outputs: 1; Number of analogue outputs: 1
Measuring range
-0.0125...0.25 bar-12.5...250 mbar-5...100.4 inH2O
Process connection threaded connection G 1/2 external thread
Application
Special feature Gold-plated contacts
Application for industrial applications
Media liquids and gases
Medium temperature -25...80
Min. bursting pressure
30000 mbar12044 inH2O3 MPa
Pressure rating
6000 mbar2400 inH2O1 MPa
Type of pressure relative pressure
Electrical data
Operating voltage 18...32 DC
Current consumption < 70; (24 V)
Min. insulation resistance 100; (500 V DC)
Protection class III
Reverse polarity protection yes
Power-on delay time 6
Integrated watchdog yes
Inputs / outputs
Number of inputs and outputs Number of digital outputs: 1; Number of analogue outputs: 1
Outputs
Total number of outputs 2
Output signal switching signal; analogue signal; (configurable)
Electrical design PNP/NPN
Number of digital outputs 1
Output function normally open / normally closed; (parameterisable)
Max. voltage drop switching output DC 2
Permanent current rating of switching output DC 250
Switching frequency DC 75
Number of analogue outputs 1
Analogue current output 4...20, invertible; (scalable)
Max. load (Ub - 10 V) / 20 mA
Short-circuit protection yes
Type of short-circuit protection pulsed
Overload protection yes
Measuring/setting range
Measuring range
-0.0125...0.25 bar-12.5...250 mbar-5...100.4 inH2O
Set point SP
-11.5...400 mbar-4.6...160.6 inH2O
Reset point rP
-12.5...399 mbar-5...160.2 inH2O
Analogue start point
-12.5...337.5 mbar-5...135.6 inH2O
Analogue end point
50...400 mbar20...160.6 inH2O
In steps of
0.5 mbar0.2 inH2O
Accuracy / deviations
Switch point accuracy < ± 0,5; (Turn down 1:1)
Repeatability < ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1)
Characteristics deviation < ± 0,25 (BFSL) / < ± 0,5 (LS); (Turn down 1:1; BFSL = Best Fit Straight Line)
Hysteresis deviation < ± 0,25; (Turn down 1:1)
Long-term stability < ± 0,1; (Turn down 1:1; per 6 months)
Temperature coefficient zero point < ± 0,2; (0...70 °C)
Temperature coefficient span < ± 0,2; (0...70 °C)
Response times
Response time < 9
Damping process value dAP 0.01...30
Damping for the analogue output dAA 0.01...30
Step response time analogue output 28
Operating conditions
Ambient temperature -20...80
Storage temperature -40...100
Protection IP 67; IP 69K
Tests / approvals
EMC
EN 61000-4-2 ESD4 kV CD / 8 kV AD
EN 61000-4-3 HF radiated10 V/m
EN 61000-4-4 Burst2 kV
EN 61000-4-5 Surge0,5/1 kV
EN 61000-4-6 HF conducted10 V
Shock resistance
DIN EN 60068-2-2750 g (11 ms)
Vibration resistance
DIN EN 60068-2-610 g (10...2000 Hz)
MTTF 103
Pressure Equipment Directive Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request
Mechanical data
Weight 563.4
Dimensions 169 x 100 x 57
Materials stainless steel (316L/1.4404); PA; FKM; PTFE; viewing glass: laminated safety glass 4 mm
Materials (wetted parts) Al2O3 (ceramics); FKM; stainless steel (316L/1.4404)
Min. pressure cycles 100 million
Process connection threaded connection G 1/2 external thread
Restrictor element integrated no (can be retrofitted)
Displays / operating elements
Display
Display unit2 x LED, green
switching statusLED, yellow
switch pointsLED ring, red
function displayalphanumeric display, red 4-digit
measured valuesanalogue display, 0...350° rotatable, pointer not visible when unit disconnected
measured valuesalphanumeric display, red 4-digit
With scale yes
Extended display range (max.)
400 mbar160.6 inH2O
Remarks
Remarks
switch point accuracy in the extended display range: 1.5 % of the span
Pack quantity 1 pcs.
Electrical connection
Connection Connector: 1 x M12; coding: A; Contacts: gold-plated