Description
PG-010KREA01-MFRKG/US/ /P
- Analogue display, pressure switch and transmitter in one unit
- Excellent readability also over a long distance
- Rotatable display with LED bar graph for switch point indication
- Hygienic, robust stainless steel housing for the requirements of the food and beverage industry
- Flush process connection for use in CIP and SIP processes
Technical data
Product characteristics | |||||||||||||
Number of inputs and outputs | Number of digital outputs: 1; Number of analogue outputs: 1 | ||||||||||||
Measuring range |
|
||||||||||||
Process connection | threaded connection G 1 external thread Aseptoflex Vario | ||||||||||||
Application | |||||||||||||
Special feature | Gold-plated contacts | ||||||||||||
Application | flush mountable for the food and beverage industry | ||||||||||||
Media | viscous media and liquids with suspended particles; liquids and gases | ||||||||||||
Medium temperature [°C] | -25...125; (145 max. 1h) | ||||||||||||
Min. bursting pressure [kPa] | 15000 | ||||||||||||
Pressure rating [kPa] | 5000 | ||||||||||||
Type of pressure | relative pressure; vacuum | ||||||||||||
No dead space | yes | ||||||||||||
MAWP (for applications according to CRN) [bar] | 50 | ||||||||||||
Electrical data | |||||||||||||
Operating voltage [V] | 18...32 DC | ||||||||||||
Current consumption [mA] | < 70; (24 V) | ||||||||||||
Min. insulation resistance [MΩ] | 100; (500 V DC) | ||||||||||||
Protection class | III | ||||||||||||
Reverse polarity protection | yes | ||||||||||||
Power-on delay time [s] | 6 | ||||||||||||
Integrated watchdog | yes | ||||||||||||
Inputs / outputs | |||||||||||||
Number of inputs and outputs | Number of digital outputs: 1; Number of analogue outputs: 1 | ||||||||||||
Outputs | |||||||||||||
Total number of outputs | 2 | ||||||||||||
Output signal | switching signal; analogue signal; (configurable) | ||||||||||||
Electrical design | PNP/NPN | ||||||||||||
Number of digital outputs | 1 | ||||||||||||
Output function | normally open / normally closed; (parameterisable) | ||||||||||||
Max. voltage drop switching output DC [V] | 2 | ||||||||||||
Permanent current rating of switching output DC [mA] | 250 | ||||||||||||
Switching frequency DC [Hz] | 50 | ||||||||||||
Number of analogue outputs | 1 | ||||||||||||
Analogue current output [mA] | 4...20, invertible; (scalable) | ||||||||||||
Max. load [Ω] | (Ub - 10 V) / 20 mA | ||||||||||||
Short-circuit protection | yes | ||||||||||||
Type of short-circuit protection | pulsed | ||||||||||||
Overload protection | yes | ||||||||||||
Measuring/setting range | |||||||||||||
Measuring range |
|
||||||||||||
Set point SP [kPa] | -98...1600 | ||||||||||||
Reset point rP [kPa] | -100...1598 | ||||||||||||
Analogue start point [kPa] | -100...1350 | ||||||||||||
Analogue end point [kPa] | 150...1600 | ||||||||||||
In steps of [kPa] | 1 | ||||||||||||
Accuracy / deviations | |||||||||||||
Switch point accuracy [% of the span] | < ± 0,2; (Turn down 1:1) | ||||||||||||
Repeatability [% of the span] | < ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1) | ||||||||||||
Characteristics deviation [% of the span] | < ± 0,2; (Turn down 1:1 , linearity, incl. hysteresis and repeatability , limit value setting to DIN EN IEC 62828-1) | ||||||||||||
Linearity deviation [% of the span] | < ± 0,15; (Turn down 1:1) | ||||||||||||
Hysteresis deviation [% of the span] | < ± 0,15; (Turn down 1:1) | ||||||||||||
Long-term stability [% of the span] | < ± 0,1; (Turn down 1:1; per year) | ||||||||||||
Temperature coefficient zero point [% of the span / 10 K] | < ± 0,05; (0...70 °C) | ||||||||||||
Temperature coefficient span [% of the span / 10 K] | < ± 0,15; (0...70 °C) | ||||||||||||
Response times | |||||||||||||
Response time [ms] | < 10 | ||||||||||||
Damping process value dAP [s] | 0.01...30 | ||||||||||||
Damping for the analogue output dAA [s] | 0.01...30 | ||||||||||||
Step response time analogue output [ms] | 25 | ||||||||||||
Operating conditions | |||||||||||||
Ambient temperature [°C] | -25...80 | ||||||||||||
Storage temperature [°C] | -40...100 | ||||||||||||
Protection | IP 67; IP 69K | ||||||||||||
Tests / approvals | |||||||||||||
EMC |
|
||||||||||||
Shock resistance |
|
||||||||||||
Vibration resistance |
|
||||||||||||
MTTF [years] | 100 | ||||||||||||
Note on approval |
|
||||||||||||
Mechanical data | |||||||||||||
Weight [g] | 524 | ||||||||||||
Materials | stainless steel (1.4404 / 316L); PA; FKM; PTFE; viewing glass: laminated safety glass 4 mm | ||||||||||||
Materials (wetted parts) | ceramics (99.9 % Al2O3); stainless steel (1.4435 / 316L); surface characteristics: Ra < 0,4 / Rz 4; PTFE | ||||||||||||
Min. pressure cycles | 100 million | ||||||||||||
Process connection | threaded connection G 1 external thread Aseptoflex Vario | ||||||||||||
Displays / operating elements | |||||||||||||
Display |
|
||||||||||||
Extended display range (max.) [kPa] | 1600 | ||||||||||||
Remarks | |||||||||||||
Remarks |
|
||||||||||||
Pack quantity | 1 pcs. | ||||||||||||
Electrical connection | |||||||||||||
Connection | Connector: 1 x M12; coding: A; Contacts: gold-plated |