Description
PI-001BREZ01-MFRKG/US/ /P
  • For use in high temperatures in the food and beverage industry
  • Robust stainless steel housing with hygienic front-flush design
  • With two-wire and three-wire connection technology
  • Reduced wiring complexity when operated as two-wire current loop
  • Integrated clamp diaphragm seal with stainless steel membrane
IO-Link features
  • Convenient operation via buttons or parameter setting via IO-Link
Technical data
Product characteristics
Number of inputs and outputs Number of digital outputs: 2; Number of analogue outputs: 1
Measuring range
-50...1000 mbar -0.73...14.5 psi -5...100 kPa
Process connection Clamp DN40 (1,5") DIN 32676 (ISO 2852)
Application
Special feature Gold-plated contacts
Application flush mountable for the food and beverage industry
Media viscous media and liquids with suspended particles; liquids and gases
Medium temperature [°C] -20...200
Min. bursting pressure
30000 mbar 435 psi 3000 kPa
Pressure rating
10000 mbar 145 psi 1000 kPa
Type of pressure relative pressure
Electrical data
Min. insulation resistance [MΩ] 100; (500 V DC)
Protection class III
Reverse polarity protection yes
Integrated watchdog yes
Operating voltage [V] 20...32 DC
Current consumption [mA] 3.6...21
Power-on delay time [s] 1
Operating voltage [V] 18...32 DC
Current consumption [mA] < 45
Power-on delay time [s] 0.5
Inputs / outputs
Number of inputs and outputs Number of digital outputs: 2; Number of analogue outputs: 1
Outputs
Total number of outputs 2
Output signal switching signal; analogue signal; IO-Link; (configurable)
Electrical design PNP/NPN
Number of digital outputs 2
Output function normally open / normally closed; (parameterisable)
Number of analogue outputs 1
Analogue current output [mA] 4...20, invertible; (scalable)
Short-circuit protection yes
Type of short-circuit protection pulsed
Overload protection yes
Max. load [Ω] 300
Max. voltage drop switching output DC [V] 2
Permanent current rating of switching output DC [mA] 250
Switching frequency DC [Hz] 125
Max. load [Ω] (Ub - 10 V) / 20 mA
Measuring/setting range
Measuring range
-50...1000 mbar -0.73...14.5 psi -5...100 kPa
Set point SP
-48...1000 mbar -0.7...14.5 psi -4.8...100 kPa
Reset point rP
-50...998 mbar -0.73...14.47 psi -0.5...99.8 kPa
Analogue start point
-50...750 mbar -0.73...10.88 psi -5...75 kPa
Analogue end point
200...1000 mbar 2.9...14.5 psi 20...100 kPa
In steps of
1 mbar 0.01 psi 0.1 kPa
Factory setting
SP1 = 250 mbar rP1 = 230 mbar
SP2 = 750 mbar rP2 = 730 mbar
ASP = 0 mbar AEP = 1000 mbar
Accuracy / deviations
Switch point accuracy [% of the span] < ± 0,2; (Turn down 1:1)
Repeatability [% of the span] < ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1)
Characteristics deviation [% of the span] < ± 0,2; (Turn down 1:1 , linearity, incl. hysteresis and repeatability , limit value setting to DIN EN IEC 62828-1)
Linearity deviation [% of the span] < ± 0,15; (Turn down 1:1)
Hysteresis deviation [% of the span] < ± 0,15; (Turn down 1:1)
Long-term stability [% of the span] < ± 0,1; (Turn down 1:1; per year)
Temperature coefficient zero point [% of the span / 10 K] < ± 0,3; (0...200 °C)
Temperature coefficient span [% of the span / 10 K] < ± 0,15; (0...200 °C)
Response times
Damping process value dAP [s] 0...30
Damping for the analogue output dAA [s] 0.01...99.99
Step response time analogue output [ms] 45
Min. response time of switching output (dAP) [ms] 3
Step response time analogue output [ms] 7
Interfaces
Communication interface IO-Link
Transmission type COM2 (38,4 kBaud)
IO-Link revision 1.0
SDCI standard IO-Link Communication Specification, Version 1.0, January 2009, Ordner No: 10.002
Profiles no profile
SIO mode yes
Required master port type A
Process data analogue 1
Process data binary 2
Min. process cycle time [ms] 2.3
Supported DeviceIDs
Type of operation DeviceID
default 106
Operating conditions
Ambient temperature [°C] -25...80
Note on ambient temperature
Medium temperature: ≤ 160 °C
Ambient temperature [°C] -25...65
Note on ambient temperature
Medium temperature: ≤ 200 °C
Storage temperature [°C] -25...100
Protection IP 67; IP 68; IP 69K
Tests / approvals
EMC
DIN EN 61000-6-2
DIN EN 61000-6-3
Shock resistance
DIN EN 60068-2-27 50 g (11 ms)
Vibration resistance
DIN EN 60068-2-6 20 g (10...2000 Hz)
MTTF [years] 142
Note on approval
Including free 6-point calibration certificate.
Mechanical data
Weight [g] 1052.2
Materials stainless steel (1.4404 / 316L); stainless steel (1.4435 / 316L); PBT; PEI; PFA
Materials (wetted parts) stainless steel (1.4435 / 316L)
Min. pressure cycles 10 million
Process connection Clamp DN40 (1,5") DIN 32676 (ISO 2852)
Surface characteristics Ra/Rz of the wetted parts < 0.38 / -
Fill fluid for pressure transmission NEOBEE (food grade, FDA compliant)
Diaphragm diameter [mm] 34
Displays / operating elements
Display
Display unit LED, green
switching status LED, yellow
function display alphanumeric display, 4-digit
measured values alphanumeric display, 4-digit
Display unit mbar; kPa; psi; inH2O; mWS; % of the span
Remarks
Pack quantity 1 pcs.
Electrical connection