Number of inputs and outputs |
Number of digital outputs: 2; Number of analogue outputs: 1 |
Measuring range |
-50...1000 mbar | -0.73...14.5 psi | -5...100 kPa |
|
Process connection |
Clamp DN50 (2") DIN 32676 (ISO 2852) |
Special feature |
Gold-plated contacts |
Application |
flush mountable for the food and beverage industry |
Media |
viscous media and liquids with suspended particles; liquids and gases |
Medium temperature [°C] |
-20...200 |
Min. bursting pressure |
30000 mbar | 435 psi | 3000 kPa |
|
Pressure rating |
10000 mbar | 145 psi | 1000 kPa |
|
Type of pressure |
relative pressure |
Min. insulation resistance [MΩ] |
100; (500 V DC) |
Protection class |
III |
Reverse polarity protection |
yes |
Integrated watchdog |
yes |
Operating voltage [V] |
20...32 DC |
Current consumption [mA] |
3.6...21 |
Power-on delay time [s] |
1 |
Operating voltage [V] |
18...32 DC |
Current consumption [mA] |
< 45 |
Power-on delay time [s] |
0.5 |
Number of inputs and outputs |
Number of digital outputs: 2; Number of analogue outputs: 1 |
Total number of outputs |
2 |
Output signal |
switching signal; analogue signal; IO-Link; (configurable) |
Electrical design |
PNP/NPN |
Number of digital outputs |
2 |
Output function |
normally open / normally closed; (parameterisable) |
Number of analogue outputs |
1 |
Analogue current output [mA] |
4...20, invertible; (scalable) |
Short-circuit protection |
yes |
Type of short-circuit protection |
pulsed |
Overload protection |
yes |
Max. load [Ω] |
300 |
Max. voltage drop switching output DC [V] |
2 |
Permanent current rating of switching output DC [mA] |
250 |
Switching frequency DC [Hz] |
125 |
Max. load [Ω] |
(Ub - 10 V) / 20 mA |
Measuring range |
-50...1000 mbar | -0.73...14.5 psi | -5...100 kPa |
|
Set point SP |
-48...1000 mbar | -0.7...14.5 psi | -4.8...100 kPa |
|
Reset point rP |
-50...998 mbar | -0.73...14.47 psi | -0.5...99.8 kPa |
|
Analogue start point |
-50...750 mbar | -0.73...10.88 psi | -5...75 kPa |
|
Analogue end point |
200...1000 mbar | 2.9...14.5 psi | 20...100 kPa |
|
In steps of |
|
Factory setting |
| SP1 = 250 mbar | rP1 = 230 mbar | | SP2 = 750 mbar | rP2 = 730 mbar | | ASP = 0 mbar | AEP = 1000 mbar |
|
Switch point accuracy [% of the span] |
< ± 0,2; (Turn down 1:1) |
Repeatability [% of the span] |
< ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1) |
Characteristics deviation [% of the span] |
< ± 0,2; (Turn down 1:1 , linearity, incl. hysteresis and repeatability , limit value setting to DIN EN IEC 62828-1) |
Linearity deviation [% of the span] |
< ± 0,15; (Turn down 1:1) |
Hysteresis deviation [% of the span] |
< ± 0,15; (Turn down 1:1) |
Long-term stability [% of the span] |
< ± 0,1; (Turn down 1:1; per year) |
Temperature coefficient zero point [% of the span / 10 K] |
< ± 0,3; (0...200 °C) |
Temperature coefficient span [% of the span / 10 K] |
< ± 0,15; (0...200 °C) |
Damping process value dAP [s] |
0...30 |
Damping for the analogue output dAA [s] |
0.01...99.99 |
Step response time analogue output [ms] |
45 |
Min. response time of switching output (dAP) [ms] |
3 |
Step response time analogue output [ms] |
7 |
Communication interface |
IO-Link |
Transmission type |
COM2 (38,4 kBaud) |
IO-Link revision |
1.0 |
SDCI standard |
IO-Link Communication Specification, Version 1.0, January 2009, Ordner No: 10.002 |
Profiles |
no profile |
SIO mode |
yes |
Required master port type |
A |
Process data analogue |
1 |
Process data binary |
2 |
Min. process cycle time [ms] |
2.3 |
Supported DeviceIDs |
Type of operation | DeviceID |
---|
default | 106 |
|
Ambient temperature [°C] |
-25...80 |
Note on ambient temperature |
Medium temperature: ≤ 160 °C |
|
Ambient temperature [°C] |
-25...65 |
Note on ambient temperature |
Medium temperature: ≤ 200 °C |
|
Storage temperature [°C] |
-25...100 |
Protection |
IP 67; IP 68; IP 69K |
EMC |
DIN EN 61000-6-2 | | DIN EN 61000-6-3 | |
|
Shock resistance |
DIN EN 60068-2-27 | 50 g (11 ms) |
|
Vibration resistance |
DIN EN 60068-2-6 | 20 g (10...2000 Hz) |
|
MTTF [years] |
142 |
Note on approval |
Including free 6-point calibration certificate. |
|
Weight [g] |
1200.45 |
Materials |
stainless steel (1.4404 / 316L); stainless steel (1.4435 / 316L); PBT; PEI; PFA |
Materials (wetted parts) |
stainless steel (1.4435 / 316L) |
Min. pressure cycles |
10 million |
Process connection |
Clamp DN50 (2") DIN 32676 (ISO 2852) |
Surface characteristics Ra/Rz of the wetted parts |
< 0.38 / - |
Fill fluid for pressure transmission |
NEOBEE (food grade, FDA compliant) |
Diaphragm diameter [mm] |
47.5 |
Display |
Display unit | LED, green | switching status | LED, yellow | function display | alphanumeric display, 4-digit | measured values | alphanumeric display, 4-digit |
|
Display unit |
mbar; kPa; psi; inH2O; mWS; % of the span |
Pack quantity |
1 pcs. |