PI2797 - Flush pressure sensor with display
PRODUCENT CODE: PI2797
CATEGORY: Full-metal housing with display for the process technology
Producer: ifm electronic
The product is in categories:
2961.45 PLN
(net)
7-14 days
The product is available on request
At the moment, the product is not available in our warehouse.
After placing the order, we will notify you of the expected delivery date of the product.
At the moment, the product is not available in our warehouse.
After placing the order, we will notify you of the expected delivery date of the product.
Fast shipping
Free delivery
from 1000 PLN (net)
Free delivery
from 1000 PLN (net)
Do you have questions about the product?
Ask an experienced consultant:
Ask an experienced consultant:
Description
PI-001BREA01-MFRKG/US/ /P
- Robust stainless steel housing for use in the food and beverage industry
- Hygienic, flush design
- Resistant to high-pressure cleaning with aggressive cleaning agents
- High temperature resistance and high protection rating
- Programmable analogue and switching output
IO-Link features
- Convenient operation via buttons or parameter setting via IO-Link
Technical data
Product characteristics | |||||||||||
Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 | ||||||||||
Measuring range |
|
||||||||||
Process connection | threaded connection G 1 external thread Aseptoflex Vario | ||||||||||
Application | |||||||||||
Special feature | Gold-plated contacts | ||||||||||
Application | flush mountable for the food and beverage industry | ||||||||||
Media | viscous media and liquids with suspended particles; liquids and gases | ||||||||||
Medium temperature [°C] | -25...125; (145 max. 1h) | ||||||||||
Min. bursting pressure |
|
||||||||||
Pressure rating |
|
||||||||||
Vacuum resistance [mbar] | -1000 | ||||||||||
Type of pressure | relative pressure | ||||||||||
No dead space | yes | ||||||||||
MAWP (for applications according to CRN) [bar] | 10 | ||||||||||
Electrical data | |||||||||||
Min. insulation resistance [MΩ] | 100; (500 V DC) | ||||||||||
Protection class | III | ||||||||||
Reverse polarity protection | yes | ||||||||||
Measuring principle | hydrostatic | ||||||||||
Integrated watchdog | yes | ||||||||||
Operating voltage [V] | 20...32 DC | ||||||||||
Current consumption [mA] | 3.6...21 | ||||||||||
Power-on delay time [s] | 1 | ||||||||||
Operating voltage [V] | 18...32 DC | ||||||||||
Current consumption [mA] | < 45 | ||||||||||
Power-on delay time [s] | 0.5 | ||||||||||
Inputs / outputs | |||||||||||
Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 | ||||||||||
Outputs | |||||||||||
Total number of outputs | 2 | ||||||||||
Output signal | switching signal; analogue signal; IO-Link; (configurable) | ||||||||||
Electrical design | PNP/NPN | ||||||||||
Number of digital outputs | 2 | ||||||||||
Output function | normally open / normally closed; (parameterisable) | ||||||||||
Number of analogue outputs | 1 | ||||||||||
Analogue current output [mA] | 4...20, invertible; (scalable) | ||||||||||
Short-circuit protection | yes | ||||||||||
Type of short-circuit protection | pulsed | ||||||||||
Overload protection | yes | ||||||||||
Max. load [Ω] | 300 | ||||||||||
Max. voltage drop switching output DC [V] | 2 | ||||||||||
Permanent current rating of switching output DC [mA] | 250 | ||||||||||
Switching frequency DC [Hz] | 125 | ||||||||||
Max. load [Ω] | (Ub - 10 V) / 20 mA | ||||||||||
Measuring/setting range | |||||||||||
Measuring range |
|
||||||||||
Set point SP |
|
||||||||||
Reset point rP |
|
||||||||||
Analogue start point |
|
||||||||||
Analogue end point |
|
||||||||||
In steps of |
|
||||||||||
Factory setting |
|
||||||||||
Accuracy / deviations | |||||||||||
Switch point accuracy [% of the span] | < ± 0,2; (Turn down 1:1) | ||||||||||
Repeatability [% of the span] | < ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1) | ||||||||||
Characteristics deviation [% of the span] | < ± 0,2; (Turn down 1:1 , linearity, incl. hysteresis and repeatability , limit value setting to DIN EN IEC 62828-1) | ||||||||||
Linearity deviation [% of the span] | < ± 0,15; (Turn down 1:1) | ||||||||||
Hysteresis deviation [% of the span] | < ± 0,15; (Turn down 1:1) | ||||||||||
Long-term stability [% of the span] | < ± 0,1; (Turn down 1:1; per year) | ||||||||||
Temperature coefficient zero point [% of the span / 10 K] | < ± 0,05; (0...70 °C) | ||||||||||
Temperature coefficient span [% of the span / 10 K] | < ± 0,15; (0...70 °C) | ||||||||||
Response times | |||||||||||
Damping process value dAP [s] | 0...30 | ||||||||||
Damping for the analogue output dAA [s] | 0.01...99.99 | ||||||||||
Step response time analogue output [ms] | 45 | ||||||||||
Min. response time of switching output (dAP) [ms] | 3 | ||||||||||
Step response time analogue output [ms] | 7 | ||||||||||
Interfaces | |||||||||||
Communication interface | IO-Link | ||||||||||
Transmission type | COM2 (38,4 kBaud) | ||||||||||
IO-Link revision | 1.0 | ||||||||||
Profiles | no profile | ||||||||||
SIO mode | yes | ||||||||||
Required master port type | A | ||||||||||
Process data analogue | 1 | ||||||||||
Process data binary | 2 | ||||||||||
Min. process cycle time [ms] | 2.3 | ||||||||||
Supported DeviceIDs |
|
||||||||||
Operating conditions | |||||||||||
Ambient temperature [°C] | -25...80 | ||||||||||
Storage temperature [°C] | -40...100 | ||||||||||
Protection | IP 67; IP 68; IP 69K | ||||||||||
Tests / approvals | |||||||||||
EMC |
|
||||||||||
Shock resistance |
|
||||||||||
Vibration resistance |
|
||||||||||
MTTF [years] | 160 | ||||||||||
Note on approval |
|
||||||||||
Mechanical data | |||||||||||
Weight [g] | 356 | ||||||||||
Materials | stainless steel (1.4404 / 316L); FKM; PTFE; PBT; PEI; PFA | ||||||||||
Materials (wetted parts) | ceramics (99.9 % Al2O3); stainless steel (1.4435 / 316L); surface characteristics: Ra < 0,4 / Rz 4; PTFE | ||||||||||
Min. pressure cycles | 100 million | ||||||||||
Process connection | threaded connection G 1 external thread Aseptoflex Vario | ||||||||||
Displays / operating elements | |||||||||||
Display |
|
||||||||||
Display unit | mbar; kPa; psi; inH2O; mWS; % of the span | ||||||||||
Remarks | |||||||||||
Pack quantity | 1 pcs. | ||||||||||
Electrical connection | |||||||||||
Connection | Connector: 1 x M12; coding: A; Contacts: gold-plated |