Number of inputs and outputs |
Number of digital outputs: 1; Number of analogue outputs: 1 |
Measuring range |
-1...16 bar | -14.6...232 psi | -0.1...1.6 MPa |
|
Process connection |
Clamp DN25...DN40 (1...1,5") DIN 32676 (ISO 2852) |
Special feature |
Gold-plated contacts |
Measuring element |
ceramic-capacitive pressure measuring cell |
Temperature monitoring |
no |
Application |
flush mountable for the food and beverage industry |
Media |
viscous media and liquids with suspended particles; liquids and gases |
Medium temperature [°C] |
-25...150 |
Min. bursting pressure |
|
Pressure rating |
|
Note on pressure rating |
take into account the pressure resistance of the bracket and the seal used for clamp connection |
|
Vacuum resistance [mbar] |
-1000 |
Type of pressure |
relative pressure; vacuum |
No dead space |
yes |
MAWP (for applications according to CRN) [bar] |
60 |
Operating voltage [V] |
18...30 DC |
Min. insulation resistance [MΩ] |
100; (500 V DC) |
Protection class |
III |
Reverse polarity protection |
yes |
Integrated watchdog |
yes |
Current consumption [mA] |
3.5...21.5 |
Power-on delay time [s] |
1 |
Current consumption [mA] |
< 45 |
Power-on delay time [s] |
0.5 |
Number of inputs and outputs |
Number of digital outputs: 1; Number of analogue outputs: 1 |
Total number of outputs |
2 |
Output signal |
analogue signal; IO-Link; (configurable) |
Number of digital outputs |
1; (IO-Link) |
Number of analogue outputs |
1 |
Analogue current output [mA] |
4...20; (scalable) |
Max. load [Ω] |
700; (Ub = 24 V; (Ub - 9 V) / 21.5 mA) |
Short-circuit proof |
yes |
Overload protection |
yes |
Measuring range |
-1...16 bar | -14.6...232 psi | -0.1...1.6 MPa |
|
Analogue start point |
-1...12.8 bar | -14.6...185.6 psi | -0.1...1.28 MPa |
|
Analogue end point |
2.2...16 bar | 32...232 psi | 0.22...1.6 MPa |
|
In steps of |
0.01 bar | 0.2 psi | 0.001 MPa |
|
Factory setting |
| ASP = 0.0 bar | AEP = 16.0 bar |
|
Repeatability [% of the span] |
< ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1) |
Characteristics deviation [% of the span] |
< ± 0,2; (linearity incl. hysteresis and repeatability, limit value setting to DIN EN IEC 62828-1) |
Linearity deviation [% of the span] |
< ± 0,15; (Turn down 1:1) |
Hysteresis deviation [% of the span] |
< ± 0,15; (Turn down 1:1) |
Long-term stability [% of the span] |
< ± 0,1; (Turn down 1:1; per year) |
Temperature coefficient zero point [% of the span / 10 K] |
< ± 0,05; (0...70 °C) |
Temperature coefficient span [% of the span / 10 K] |
< ± 0,15; (0...70 °C) |
Total deviation over temperature range |
Temperature range | total deviation |
---|
-25...15 °C | Characteristics deviation ± 0,05 % of the span / 10 K | 15...80 °C | Characteristics deviation | 80...150 °C | Characteristics deviation ± 0,1 % of the span / 10 K |
|
Notes on the accuracy / deviation |
for further details see section Diagrams and graphs |
Damping for the analogue output dAA [s] |
0...4 |
Step response time analogue output [ms] |
30 |
Step response time analogue output [ms] |
7 |
Communication interface |
IO-Link |
Transmission type |
COM2 (38,4 kBaud) |
IO-Link revision |
1.1 |
SDCI standard |
IEC 61131-9 |
Profiles |
Digital Measuring Sensor (0x000A), Identification and Diagnosis (0x4000) |
SIO mode |
no |
Required master port type |
A |
Process data analogue |
3 |
Min. process cycle time [ms] |
3.2 |
IO-Link resolution pressure [bar] |
0.005 |
IO-Link process data (cyclical) |
function | bit length |
---|
pressure | 16 | device status | 4 |
|
IO-Link functions (acyclical) |
application specific tag; internal temperature |
Supported DeviceIDs |
Type of operation | DeviceID |
---|
default | 661 |
|
Ambient temperature [°C] |
-25...80 |
Storage temperature [°C] |
-40...100 |
Protection |
IP 67; IP 68; IP 69K |
EMC |
DIN EN 61000-6-2 | | DIN EN 61000-6-3 | |
|
Shock resistance |
DIN EN 60068-2-27 | 50 g (11 ms) |
|
Vibration resistance |
DIN EN 60068-2-6 | 20 g (10...2000 Hz) |
|
MTTF [years] |
323 |
Note on approval |
factory certificate available as download at www.factory-certificate.ifm |
|
UL approval |
UL Approval no. | J055 | File number UL | E174189 |
|
Weight [g] |
392 |
Materials |
stainless steel (1.4404 / 316L); PBT |
Materials (wetted parts) |
ceramics (99.9 % Al2O3); stainless steel (1.4435 / 316L); surface characteristics: Ra < 0,4 / Rz 4; PTFE |
Min. pressure cycles |
100 million |
Process connection |
Clamp DN25...DN40 (1...1,5") DIN 32676 (ISO 2852) |
Pack quantity |
1 pcs. |
Connection |
Connector: 1 x M12; coding: A; Contacts: gold-plated |
ambient temperature influence on the accuracy |
X | temperature |
---|
Y | total deviation |
---|
|