« Back
PN2093 - Pressure sensor with display

PN2093 - Pressure sensor with display

PRODUCENT CODE: PN2093
CATEGORY: Type PN / PE with digital display
Producer: ifm electronic
1802.16 PLN
(net)
7-14 days
The product is available on request
At the moment, the product is not available in our warehouse.
After placing the order, we will notify you of the expected delivery date of the product.
Fast shipping
Free delivery
from 1000 PLN (net)
Do you have questions about the product?
Ask an experienced consultant:
+48 32 237 61 98 w. 101
bn@newtech.com.pl
Description
PN-025-RER14-MFRKG/US/ /V
  • Two switching outputs, one of them programmable as IO-Link and one as analogue output
  • Red/green display for clear identification of the acceptable range
  • The process connection can be rotated for optimum alignment
  • With long-term stability thanks to high overload protection
  • Robust design for use in harsh industrial environments
Technical data
Product characteristics
Number of inputs and outputs Number of digital outputs: 2; Number of analogue outputs: 1
Measuring range
-1...25 bar-14.5...362.5 psi-0.1...2.5 MPa
Process connection threaded connection G 1/4 internal thread (DIN EN ISO 1179-2)
Application
Special feature Gold-plated contacts
Measuring element ceramic-capacitive pressure measuring cell
Application for industrial applications
Media liquids and gases
Medium temperature -25...80
Min. bursting pressure
350 bar5075 psi35 MPa
Pressure rating
150 bar2175 psi15 MPa
Vacuum resistance
-1000 mbar-0.1 MPa
Type of pressure relative pressure; vacuum
Electrical data
Operating voltage 18...30 DC; (to SELV/PELV)
Current consumption < 35
Min. insulation resistance 100; (500 V DC)
Protection class III
Reverse polarity protection yes
Power-on delay time 0.3
Integrated watchdog yes
Inputs / outputs
Number of inputs and outputs Number of digital outputs: 2; Number of analogue outputs: 1
Outputs
Total number of outputs 2
Output signal switching signal; analogue signal; IO-Link; (configurable)
Electrical design PNP/NPN
Number of digital outputs 2
Output function normally open / normally closed; (parameterisable)
Max. voltage drop switching output DC 2
Permanent current rating of switching output DC 250
Switching frequency DC < 500
Number of analogue outputs 1
Analogue current output 4...20; (scalable 1:5)
Max. load 500
Analogue voltage output 0...10; (scalable 1:5)
Min. load resistance 2000
Short-circuit protection yes
Type of short-circuit protection pulsed
Overload protection yes
Measuring/setting range
Measuring range
-1...25 bar-14.5...362.5 psi-0.1...2.5 MPa
Analogue start point
-1...20 bar-14.5...290 psi-0.1...2 MPa
Analogue end point
4...25 bar58...362.5 psi0.4...2.5 MPa
Factory setting / CMPT = 2
Set point SP
-0.85...25 bar-12...362.5 psi-0.085...2.5 MPa
Reset point rP
-0.95...24.9 bar-13.5...361 psi-0.095...2.49 MPa
Min. difference between SP and rP
0.15 bar1.5 psi0.015 MPa
In steps of
0.05 bar0.5 psi0.005 MPa
Status_B High Resolution / CMPT = 3
Set point SP
-0.84...25 bar-12.2...362.6 psi-0.084...2.5 MPa
Reset point rP
-0.95...24.9 bar-13.7...361.1 psi-0.095...2.49 MPa
Min. difference between SP and rP
0.11 bar1.5 psi0.011 MPa
In steps of
0.01 bar0.1 psi0.001 MPa
Accuracy / deviations
Switch point accuracy < ± 0,4; (Turn down 1:1)
Repeatability < ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1)
Characteristics deviation < ± 0,25 (BFSL) / < ± 0,5 (LS); (Turn down 1:1; BFSL = Best Fit Straight Line; LS = limit value setting)
Hysteresis deviation < ± 0,1; (Turn down 1:1)
Long-term stability < ± 0,05; (Turn down 1:1; per 6 months)
Temperature coefficient zero point < ± 0,2; (-0...80 °C)
Temperature coefficient span < ± 0,2; (-0...80 °C)
Notes on the accuracy / deviation switch point accuracy, linearity error under DNV GL: < ± 1%: < ± 1%
Response times
Response time < 1.5
Delay time programmable dS, dr 0...50
Damping process value dAP 0...4
Damping for the analogue output dAA 0...4
Max. response time analogue output 3
Software / programming
Parameter setting options hysteresis / window; normally open / normally closed; switch-on/switch-off delay; Damping; Display unit; current/voltage output
Interfaces
Communication interface IO-Link
Transmission type COM2 (38,4 kBaud)
IO-Link revision 1.1
SDCI standard IEC 61131-9
SIO mode yes
Required master port type A; (when pin 2 not connected: B)
Supported DeviceIDs
Type of operationDeviceID
Factory setting / CMPT = 2462
Status_B High Resolution / CMPT = 3973
Note
For further information please see the IODD PDF file under "Downloads"
Factory setting / CMPT = 2
Profiles Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis
Min. process cycle time 2.3
IO-Link resolution pressure 0.01
IO-Link process data (cyclical)
functionbit length
pressure14
binary switching information2
IO-Link functions (acyclical) application specific tag
Status_B High Resolution / CMPT = 3
Profiles Smart Sensor ED2: Digital Measuring Sensor (0x000A), Identification and Diagnosis (0x4000)
Min. process cycle time 3
IO-Link resolution pressure 0.01
IO-Link process data (cyclical)
functionbit length
pressure16
device status4
binary switching information2
IO-Link functions (acyclical) application specific tag
Operating conditions
Ambient temperature -25...80
Storage temperature -40...100
Protection IP 65; IP 67
Tests / approvals
EMC
DIN EN 61000-6-2
DIN EN 61000-6-3
Shock resistance
DIN EN 60068-2-2750 g (11 ms)
Vibration resistance
DIN EN 60068-2-620 g (10...2000 Hz)
MTTF 138
UL approval
UL Approval no.J012
Pressure Equipment Directive Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request
Mechanical data
Weight 238.5
Housing cylindrical
Dimensions Ø 34 / L = 90.7
Materials stainless steel (316L/1.4404); PBT+PC-GF30; PBT-GF20; PC
Materials (wetted parts) stainless steel (316L/1.4404); Al2O3 (ceramics); FKM
Min. pressure cycles 100 million
Tightening torque 25...35; (recommended tightening torque; depends on lubrication, seal and pressure rating)
Process connection threaded connection G 1/4 internal thread (DIN EN ISO 1179-2)
Restrictor element integrated no (can be retrofitted)
Displays / operating elements
Display
Display unit3 x LED, green (bar, psi, MPa)
switching status2 x LED, yellow
measured valuesalphanumeric display, red/green 4-digit
Remarks
Pack quantity 1 pcs.
Electrical connection
Connection Connector: 1 x M12; coding: A; Contacts: gold-plated