« Back
PN2696 - Pressure sensor with display

PN2696 - Pressure sensor with display

PRODUCENT CODE: PN2696
CATEGORY: Type PN / PE with digital display
Producer: ifm electronic
1821.64 PLN
(net)
7-14 days
The product is available on request
At the moment, the product is not available in our warehouse.
After placing the order, we will notify you of the expected delivery date of the product.
Fast shipping
Free delivery
from 1000 PLN (net)
Do you have questions about the product?
Ask an experienced consultant:
+48 32 237 61 98 w. 101
bn@newtech.com.pl
Description
PN-2,5-REN14-MFRKG/US/ /V
  • Two switching outputs, one of them programmable as IO-Link and one as analogue output
  • Red/green display for clear identification of the acceptable range
  • The process connection can be rotated for optimum alignment
  • With long-term stability thanks to high overload protection
  • Robust design for use in harsh industrial environments
Technical data
Product characteristics
Number of inputs and outputs Number of digital outputs: 2; Number of analogue outputs: 1
Measuring range
-0.125...2.5 bar-125...2500 mbar-1.8...36.25 psi-12.5...250 kPa
Process connection threaded connection 1/4" NPT external thread
Application
Special feature Gold-plated contacts
Measuring element ceramic-capacitive pressure measuring cell
Application for industrial applications
Media liquids and gases
Medium temperature -25...80
Min. bursting pressure
50 bar725 psi5000 kPa
Pressure rating
20 bar290 psi2000 kPa
Vacuum resistance -1000
Type of pressure relative pressure
MAWP (for applications according to CRN)
20 bar290 psi2000 kPa
Electrical data
Operating voltage 18...30 DC; (to SELV/PELV)
Current consumption < 35
Min. insulation resistance 100; (500 V DC)
Protection class III
Reverse polarity protection yes
Power-on delay time 0.3
Integrated watchdog yes
Inputs / outputs
Number of inputs and outputs Number of digital outputs: 2; Number of analogue outputs: 1
Outputs
Total number of outputs 2
Output signal switching signal; analogue signal; IO-Link; (configurable)
Electrical design PNP/NPN
Number of digital outputs 2
Output function normally open / normally closed; (parameterisable)
Max. voltage drop switching output DC 2
Permanent current rating of switching output DC 250
Switching frequency DC < 500
Number of analogue outputs 1
Analogue current output 4...20; (scalable 1:5)
Max. load 500
Analogue voltage output 0...10; (scalable 1:5)
Min. load resistance 2000
Short-circuit protection yes
Type of short-circuit protection pulsed
Overload protection yes
Measuring/setting range
Measuring range
-0.125...2.5 bar-125...2500 mbar-1.8...36.25 psi-12.5...250 kPa
Analogue start point
-0.125...2 bar-1.8...29 psi-12.5...200 kPa
Analogue end point
0.375...2.5 bar5.45...36.25 psi37.5...250 kPa
Factory setting / CMPT = 2
Set point SP
-0.11...2.5 bar-1.6...36.25 psi-11...250 kPa
Reset point rP
-0.12...2.49 bar-1.75...36.1 psi-12...249 kPa
Min. difference between SP and rP
0.015 bar0.15 psi1.5 kPa
In steps of
0.005 bar0.05 psi0.5 kPa
Status_B High Resolution / CMPT = 3
Set point SP
-0.109...2.5 bar-1.58...36.26 psi-10.9...250 kPa
Reset point rP
-0.12...2.49 bar-1.73...36.11 psi-12...249 kPa
Min. difference between SP and rP
0.011 bar0.15 psi1.1 kPa
In steps of
0.001 bar0.01 psi0.1 kPa
Accuracy / deviations
Switch point accuracy < ± 0,4; (Turn down 1:1)
Repeatability < ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1)
Characteristics deviation < ± 0,25 (BFSL) / < ± 0,5 (LS); (Turn down 1:1; BFSL = Best Fit Straight Line; LS = limit value setting)
Hysteresis deviation < ± 0,1; (Turn down 1:1)
Long-term stability < ± 0,05; (Turn down 1:1; per 6 months)
Temperature coefficient zero point < ± 0,2; (-0...80 °C)
Temperature coefficient span < ± 0,2; (-0...80 °C)
Notes on the accuracy / deviation switch point accuracy, linearity error under DNV GL: < ± 1%: < ± 1%
Response times
Response time < 1.5
Delay time programmable dS, dr 0...50
Damping process value dAP 0...4
Damping for the analogue output dAA 0...4
Max. response time analogue output 3
Software / programming
Parameter setting options hysteresis / window; normally open / normally closed; switch-on/switch-off delay; Damping; Display unit; current/voltage output
Interfaces
Communication interface IO-Link
Transmission type COM2 (38,4 kBaud)
IO-Link revision 1.1
SDCI standard IEC 61131-9
SIO mode yes
Required master port type A; (when pin 2 not connected: B)
Supported DeviceIDs
Type of operationDeviceID
Factory setting / CMPT = 2474
Status_B High Resolution / CMPT = 3990
Note
For further information please see the IODD PDF file under "Downloads"
Factory setting / CMPT = 2
Profiles Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis
Min. process cycle time 2.3
IO-Link resolution pressure 0.001
IO-Link process data (cyclical)
functionbit length
pressure14
binary switching information2
IO-Link functions (acyclical) application specific tag
Status_B High Resolution / CMPT = 3
Profiles Smart Sensor ED2: Digital Measuring Sensor (0x000A), Identification and Diagnosis (0x4000)
Min. process cycle time 3
IO-Link resolution pressure 0.001
IO-Link process data (cyclical)
functionbit length
pressure16
device status4
binary switching information2
IO-Link functions (acyclical) application specific tag
Operating conditions
Ambient temperature -25...80
Storage temperature -40...100
Protection IP 65; IP 67
Tests / approvals
EMC
DIN EN 61000-6-2
DIN EN 61000-6-3
Shock resistance
DIN EN 60068-2-2750 g (11 ms)
Vibration resistance
DIN EN 60068-2-620 g (10...2000 Hz)
MTTF 138
UL approval
UL Approval no.J012
Pressure Equipment Directive Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request
Mechanical data
Weight 245
Housing cylindrical
Dimensions Ø 34 / L = 90.7
Materials stainless steel (316L/1.4404); PBT+PC-GF30; PBT-GF20; PC
Materials (wetted parts) stainless steel (316L/1.4404); AI2O3 (96%; ceramics); FKM
Min. pressure cycles 100 million
Tightening torque > 50; (depends on lubrication, seal and pressure rating)
Process connection threaded connection 1/4" NPT external thread
Restrictor element integrated no (can be retrofitted)
Displays / operating elements
Display
Display unit3 x LED, green (bar, psi, kPa)
switching status2 x LED, yellow
measured valuesalphanumeric display, red/green 4-digit
Remarks
Pack quantity 1 pcs.
Electrical connection
Connection Connector: 1 x M12; coding: A; Contacts: gold-plated