PNI022 - Pressure sensor with analogue input
PRODUCENT CODE: PNI022
CATEGORY: Pressure switches for filter monitoring
Producer: ifm electronic
2479.24 PLN
(net)
7-14 days
The product is available on request
At the moment, the product is not available in our warehouse.
After placing the order, we will notify you of the expected delivery date of the product.
At the moment, the product is not available in our warehouse.
After placing the order, we will notify you of the expected delivery date of the product.
Fast shipping
Free delivery
from 1000 PLN (net)
Free delivery
from 1000 PLN (net)
Do you have questions about the product?
Ask an experienced consultant:
Ask an experienced consultant:
Description
PNI100-SBR14-QFRKG/US/ /V
- Evaluation of external voltage or current values
- Continuous comparison of set/actual values directly in the sensor
- Automatic adjustment of the switch point
- Clearly visible 4-digit LED display
- Efficient differential pressure monitoring
Technical data
Product characteristics | |||||||||||
Number of inputs and outputs | Number of digital outputs: 2 | ||||||||||
Measuring range [bar] | 0...100 | ||||||||||
Process connection | threaded connection G 1/4 internal thread | ||||||||||
Application | |||||||||||
Special feature | Gold-plated contacts | ||||||||||
Application | for industrial applications | ||||||||||
Media | liquids and gases | ||||||||||
Conditionally suitable for | use in gases at pressures &rt; 25 bar only on request | ||||||||||
Medium temperature [°C] | -25...80 | ||||||||||
Min. bursting pressure [bar] | 650 | ||||||||||
Pressure rating [bar] | 300 | ||||||||||
Type of pressure | relative pressure | ||||||||||
Electrical data | |||||||||||
Operating voltage [V] | 18...30 DC | ||||||||||
Current consumption [mA] | < 90 | ||||||||||
Min. insulation resistance [MΩ] | 100; (500 V DC) | ||||||||||
Protection class | III | ||||||||||
Reverse polarity protection | yes | ||||||||||
Power-on delay time [s] | 0.2 | ||||||||||
Integrated watchdog | yes | ||||||||||
Inputs / outputs | |||||||||||
Number of inputs and outputs | Number of digital outputs: 2 | ||||||||||
Inputs | |||||||||||
Analogue input (current) [mA] | 0...20 | ||||||||||
Max. load [Ω] | 300 | ||||||||||
Analogue input (voltage) [V] | 0...10 | ||||||||||
Min. load resistance [Ω] | 90000 | ||||||||||
Outputs | |||||||||||
Total number of outputs | 2 | ||||||||||
Output signal | switching signal | ||||||||||
Electrical design | PNP/NPN | ||||||||||
Number of digital outputs | 2 | ||||||||||
Output function | normally open / normally closed; (parameterisable) | ||||||||||
Max. voltage drop switching output DC [V] | 2 | ||||||||||
Permanent current rating of switching output DC [mA] | 250 | ||||||||||
Switching frequency DC [Hz] | < 170 | ||||||||||
Short-circuit protection | yes | ||||||||||
Type of short-circuit protection | pulsed | ||||||||||
Overload protection | yes | ||||||||||
Measuring/setting range | |||||||||||
Measuring range [bar] | 0...100 | ||||||||||
Set point SP [bar] | -24.6...100 | ||||||||||
Note on setpoint SP |
|
||||||||||
Reset point rP [bar] | -25...99.6 | ||||||||||
Note on reset point rP |
|
||||||||||
In steps of [bar] | 0.2 | ||||||||||
Accuracy / deviations | |||||||||||
Characteristics deviation [% of the final value] | < ± 0,6 | ||||||||||
Temperature drift per 10 K | < ± 0.3 | ||||||||||
Characteristics deviation analogue input | < ± 0.3 | ||||||||||
Temperature drift analogue input per 10 K | < ± 0.1 | ||||||||||
Temperature drift analogue input [°C] | 0...80 | ||||||||||
Response times | |||||||||||
Response time [ms] | < 3 | ||||||||||
Delay time programmable dS, dr [s] | 0, 0,1...50 | ||||||||||
Damping process value dAP [s] | 0...4 | ||||||||||
Software / programming | |||||||||||
Adjustment of the switch point | programming button | ||||||||||
Parameter setting options | hysteresis / window; normally open / normally closed; switching logic; current/voltage input; Damping; adaptation of displayed values; display can be rotated and switched off; Display unit | ||||||||||
Operating conditions | |||||||||||
Ambient temperature [°C] | -25...80 | ||||||||||
Storage temperature [°C] | -40...100 | ||||||||||
Protection | IP 67 | ||||||||||
Tests / approvals | |||||||||||
EMC |
|
||||||||||
Shock resistance |
|
||||||||||
Vibration resistance |
|
||||||||||
MTTF [years] | 152 | ||||||||||
Pressure Equipment Directive | Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request | ||||||||||
Mechanical data | |||||||||||
Weight [g] | 291.5 | ||||||||||
Materials | stainless steel (1.4305 / 303); PBT; PC; PA; FKM | ||||||||||
Materials (wetted parts) | stainless steel (1.4305 / 303); ceramics; FKM | ||||||||||
Min. pressure cycles | 100 million | ||||||||||
Process connection | threaded connection G 1/4 internal thread | ||||||||||
Restrictor element integrated | no (can be retrofitted) | ||||||||||
Displays / operating elements | |||||||||||
Display |
|
||||||||||
Display unit | bar; psi; MPa | ||||||||||
Remarks | |||||||||||
Pack quantity | 1 pcs. | ||||||||||
Electrical connection | |||||||||||
Connection | Connector: 1 x M12; coding: A; Contacts: gold-plated |