PQ3834 - Pressure sensor for pneumatics
PRODUCENT CODE: PQ3834
CATEGORY: Compact housing with display for pneumatics
Producer: ifm electronic
709.97 PLN
(net)
7-14 days
The product is available on request
At the moment, the product is not available in our warehouse.
After placing the order, we will notify you of the expected delivery date of the product.
At the moment, the product is not available in our warehouse.
After placing the order, we will notify you of the expected delivery date of the product.
Fast shipping
Free delivery
from 1000 PLN (net)
Free delivery
from 1000 PLN (net)
Do you have questions about the product?
Ask an experienced consultant:
Ask an experienced consultant:
Description
PQ-010-KHR18-KFPKG/AS/
- Reliable monitoring of the system pressure in pneumatics and in compressed air systems
- Very high overpressure and vacuum resistance
- Clearly visible slanted LED display
- Red/green display for clear identification of the acceptable range
- With programmable switching output and analogue output
IO-Link features
- Convenient operation via buttons or parameter setting via IO-Link
Technical data
Product characteristics | |||||||||
Number of inputs and outputs | Number of digital outputs: 1; Number of analogue outputs: 1 | ||||||||
Measuring range |
|
||||||||
Process connection | threaded connection G 1/8 internal thread internal thread:M5 | ||||||||
Application | |||||||||
Special feature | Gold-plated contacts | ||||||||
Application | for industrial applications | ||||||||
Conditionally suitable for | other media on request | ||||||||
Medium temperature [°C] | 0...60 | ||||||||
Min. bursting pressure |
|
||||||||
Note on min. burst pressure |
|
||||||||
Pressure rating |
|
||||||||
Vacuum resistance [mbar] | -1000 | ||||||||
Type of pressure | relative pressure; differential pressure; vacuum | ||||||||
Electrical data | |||||||||
Operating voltage [V] | 18...32 DC; (to SELV/PELV) | ||||||||
Current consumption [mA] | < 50 | ||||||||
Min. insulation resistance [MΩ] | 100; (500 V DC) | ||||||||
Protection class | III | ||||||||
Reverse polarity protection | yes | ||||||||
Overvoltage protection | yes; (< 40 V) | ||||||||
Power-on delay time [s] | 0.5 | ||||||||
Integrated watchdog | yes | ||||||||
Inputs / outputs | |||||||||
Number of inputs and outputs | Number of digital outputs: 1; Number of analogue outputs: 1 | ||||||||
Outputs | |||||||||
Total number of outputs | 2 | ||||||||
Output signal | switching signal; analogue signal; IO-Link; (configurable) | ||||||||
Electrical design | PNP | ||||||||
Number of digital outputs | 1 | ||||||||
Output function | normally open / normally closed; (parameterisable) | ||||||||
Max. voltage drop switching output DC [V] | 2 | ||||||||
Permanent current rating of switching output DC [mA] | 100 | ||||||||
Switching frequency DC [Hz] | < 100 | ||||||||
Number of analogue outputs | 1 | ||||||||
Analogue current output [mA] | 4...20 | ||||||||
Max. load [Ω] | 500 | ||||||||
Short-circuit protection | yes | ||||||||
Type of short-circuit protection | pulsed | ||||||||
Measuring/setting range | |||||||||
Measuring range |
|
||||||||
Set point SP |
|
||||||||
Reset point rP |
|
||||||||
In steps of |
|
||||||||
Accuracy / deviations | |||||||||
Switch point accuracy [% of the span] | < ± 0,5 | ||||||||
Repeatability [% of the span] | < ± 0,1; (with temperature fluctuations < 10 K) | ||||||||
Characteristics deviation [% of the span] | < ± 0,25 (BFSL) / < ± 0,5 (LS); (BFSL = Best Fit Straight Line; LS = limit value setting) | ||||||||
Hysteresis deviation [% of the span] | < ± 0,25 | ||||||||
Long-term stability [% of the span] | < ± 0,05; (per 6 months) | ||||||||
Temperature coefficient zero point [% of the span / 10 K] | 0,2; (0...60 °C) | ||||||||
Temperature coefficient span [% of the span / 10 K] | 0,2; (0...60 °C) | ||||||||
Response times | |||||||||
Response time [ms] | < 6 | ||||||||
Delay time programmable dS, dr [s] | 0; 0,002...5 | ||||||||
Step response time analogue output [ms] | 6 | ||||||||
Software / programming | |||||||||
Parameter setting options | hysteresis / window; normally open / normally closed; analogue output; IO-Link; switching logic; switch-on/switch-off delay; Damping; Display unit | ||||||||
Interfaces | |||||||||
Communication interface | IO-Link | ||||||||
Transmission type | COM2 (38,4 kBaud) | ||||||||
IO-Link revision | 1.1 | ||||||||
SDCI standard | IEC 61131-9 FDIS | ||||||||
Profiles | Smart Sensor: Process Data Variable; Device Identification | ||||||||
SIO mode | yes | ||||||||
Required master port type | A | ||||||||
Process data analogue | 1 | ||||||||
Process data binary | 2 | ||||||||
Min. process cycle time [ms] | 2.3 | ||||||||
Supported DeviceIDs |
|
||||||||
Operating conditions | |||||||||
Ambient temperature [°C] | 0...70 | ||||||||
Storage temperature [°C] | -25...85 | ||||||||
Protection | IP 65 | ||||||||
Tests / approvals | |||||||||
EMC |
|
||||||||
Shock resistance |
|
||||||||
Vibration resistance |
|
||||||||
MTTF [years] | 437 | ||||||||
Pressure Equipment Directive | Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request | ||||||||
Mechanical data | |||||||||
Weight [g] | 87 | ||||||||
Materials | PBT; FKM; polyester | ||||||||
Materials (wetted parts) | brass; FKM; silicon (coated); PBT | ||||||||
Min. pressure cycles | 50 million | ||||||||
Process connection | threaded connection G 1/8 internal thread internal thread:M5 | ||||||||
Displays / operating elements | |||||||||
Display |
|
||||||||
Display unit | bar; kPa; psi; inHg | ||||||||
Remarks | |||||||||
Pack quantity | 1 pcs. | ||||||||
Electrical connection | |||||||||
Connection | Connector: 1 x M8; coding: A; Contacts: gold-plated |