Number of inputs and outputs |
Number of digital outputs: 2 |
Measuring range |
0...100 bar | 0...1450 psi | 0...10 MPa |
|
Process connection |
threaded connection G 1/8 external thread (DIN EN ISO 1179-2); internal thread:M5 |
Measuring element |
metallic thin film cell |
Application |
for industrial applications |
Media |
liquids and gases |
Medium temperature |
-40...90 |
Min. bursting pressure |
|
Pressure rating |
|
Note on pressure rating |
|
Vacuum resistance |
|
Type of pressure |
relative pressure |
Operating voltage |
18...30 DC |
Current consumption |
< 15 |
Min. insulation resistance |
100; (500 V DC) |
Protection class |
III |
Reverse polarity protection |
yes |
Power-on delay time |
< 0.3 |
Number of inputs and outputs |
Number of digital outputs: 2 |
Total number of outputs |
2 |
Output signal |
switching signal; IO-Link; (configurable) |
Electrical design |
PNP/NPN |
Number of digital outputs |
2 |
Output function |
normally open / normally closed; (parameterisable) |
Max. voltage drop switching output DC |
2 |
Permanent current rating of switching output DC |
100 |
Switching frequency DC |
< 170 |
Short-circuit protection |
yes |
Type of short-circuit protection |
pulsed |
Overload protection |
yes |
Measuring range |
0...100 bar | 0...1450 psi | 0...10 MPa |
|
Set point SP |
1...100 bar | 15...1450 psi | 0.1...10 MPa |
|
Reset point rP |
0.5...99.5 bar | 7...1433 psi | 0.05...9.95 MPa |
|
In steps of |
|
Factory setting |
SP1 = 65 bar | rP1 = 60 bar | ou1 = Hno; | SP2 = 4 bar | rP2 = 2 bar | ou2 = Hnc; | dS1/dS2 = 0 ms | dr1/dr2 = 0 ms | | coF = 0 % | P-n = PnP | dAP= 60 ms |
|
Switch point accuracy |
< ± 0,5 (nach DIN EN 61298-2) |
Repeatability |
< ± 0,05; (with temperature fluctuations < 10 K) |
Characteristics deviation |
< ± 0,5; (linearity incl. hysteresis and repeatability, limit value setting to DIN EN IEC 62828-1) |
Linearity deviation |
< ± 0,1 (BFSL) / < ± 0,2 (LS) |
Hysteresis deviation |
< ± 0,2 |
Long-term stability |
< ± 0,1; (per 6 months) |
Temperature coefficient zero point |
< 0,1 (-25...90 °C) / < 0,2 (-40...-25 °C) |
Temperature coefficient span |
< 0,1 (-25...90 °C) / < 0,2 (-40...-25 °C) |
Response time |
< 3 |
Parameter setting options |
hysteresis / window; normally open / normally closed; switching logic; switch-on/switch-off delay; Damping |
Communication interface |
IO-Link |
Transmission type |
COM2 (38,4 kBaud) |
IO-Link revision |
1.1 |
SDCI standard |
IEC 61131-9 |
Profiles |
Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis |
SIO mode |
yes |
Required master port type |
A |
Process data analogue |
2 |
Process data binary |
2 |
Min. process cycle time |
5 |
Supported DeviceIDs |
Type of operation | DeviceID | default | 1565 |
|
Ambient temperature |
-40...90 |
Storage temperature |
-40...100 |
Protection |
IP 67; IP 69K |
EMC |
|
Shock resistance |
DIN EN 60068-2-27 | 500 g (1 ms) |
|
Vibration resistance |
DIN EN 60068-2-6 | 20 g (10...2000 Hz) |
|
MTTF |
667 |
UL approval |
UL Approval no. | J016 | File number UL | E174189 |
|
Pressure Equipment Directive |
Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
Weight |
55.5 |
Housing |
cylindrical |
Dimensions |
Ø 19 / L = 65 |
Materials |
stainless steel (630/1.4542/17-4 PH); stainless steel (316L/1.4404); PEI |
Materials (wetted parts) |
stainless steel (303/1.4305); stainless steel (630/1.4542/17-4 PH) |
Min. pressure cycles |
60 million; (at 1.2 times nominal pressure) |
Tightening torque |
20...25; (recommended tightening torque; depends on lubrication, seal and pressure rating) |
Process connection |
threaded connection G 1/8 external thread (DIN EN ISO 1179-2); internal thread:M5 |
Process connection sealing |
FKM (DIN EN ISO 1179-2) |
Restrictor element integrated |
yes |
Remarks |
BFSL = Best Fit Straight Line | LS = limit value setting |
|
Pack quantity |
1 pcs. |
Connection |
Connector: 1 x M12; coding: A |