« Back
PX3289 - Pressure transmitter with ceramic measuring cell

PX3289 - Pressure transmitter with ceramic measuring cell

PRODUCENT CODE: PX3289
CATEGORY: Transmitters type PA
Producer: ifm electronic
1232.67 PLN
(net)
7-14 days
The product is available on request
At the moment, the product is not available in our warehouse.
After placing the order, we will notify you of the expected delivery date of the product.
Fast shipping
Free delivery
from 1000 PLN (net)
Do you have questions about the product?
Ask an experienced consultant:
+48 32 237 61 98 w. 101
bn@newtech.com.pl
Description
PA-,10BRBN14-A-ZVG/US/ /V
  • Reliable detection of system pressure in industrial and mobile applications
  • Precise analogue output
  • With long-term stability thanks to high overload protection
  • Lifespan of more than 100 million pressure cycles
  • High shock and vibration resistance
Technical data
Product characteristics
Number of inputs and outputs Number of analogue outputs: 1
Measuring range
0...0.1 bar 0...100 mbar 0...1.45 psi 0...40.16 inH2O 0...10 kPa
Process connection threaded connection 1/4" NPT external thread internal thread:M5
Application
Special feature Gold-plated contacts
Application for industrial applications
Media liquids and gases
Medium temperature [°C] -25...90; (on request: -40...90 °C)
Min. bursting pressure
30000 mbar 435 psi 12030 inH2O 3000 kPa
Pressure rating
4000 mbar 58 psi 1606 inH2O 400 kPa
Type of pressure relative pressure
Electrical data
Operating voltage [V] 9.6...32 DC
Min. insulation resistance [MΩ] 100; (500 V DC)
Protection class III
Reverse polarity protection yes
Inputs / outputs
Number of inputs and outputs Number of analogue outputs: 1
Outputs
Total number of outputs 1
Output signal analogue signal
Number of analogue outputs 1
Analogue current output [mA] 4...20
Max. load [Ω] 720; (Ub = 24 V; (Ub - 9,6 V) / 20 mA)
Overload protection yes
Measuring/setting range
Measuring range
0...0.1 bar 0...100 mbar 0...1.45 psi 0...40.16 inH2O 0...10 kPa
Accuracy / deviations
Repeatability [% of the span] < 0,2; (with temperature fluctuations < 10 K)
Characteristics deviation [% of the span] < ± 0,5 (BFSL) / < ± 1 (LS); (BFSL = Best Fit Straight Line; LS = limit value setting)
Long-term stability [% of the span] < ± 0,1; (per 6 months)
Temperature coefficient zero point [% of the span / 10 K] < ± 0,5; (0...80 °C)
Temperature coefficient span [% of the span / 10 K] < ± 0,5; (0...80 °C)
Response times
Step response time analogue output [ms] 3
Operating conditions
Ambient temperature [°C] -25...80
Storage temperature [°C] -40...100
Protection IP 68
Tests / approvals
EMC
EN 61000-4-2 ESD 4 kV CD / 8 kV AD
EN 61000-4-3 HF radiated 30 V/m
EN 61000-4-4 Burst 2 kV
EN 61000-4-6 HF conducted 10 V
radiation of interference according to the automotive directive 2004/104/EC
CISPR 25
immunity according to the automotive directive 2004/104/EC
ISO 11452-2 HF radiated 100 V/m
ISO 7637-2 pulse severity level 3
Shock resistance
DIN EN 60068-2-27 50 g (11 ms)
DIN EN 61373 category 3
Vibration resistance
DIN EN 60068-2-6 20 g (10...2000 Hz)
DIN EN 61373 category 2
MTTF [years] 555
UL approval
File number UL E174189
Pressure Equipment Directive Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request
Mechanical data
Weight [g] 210.1
Materials stainless steel (1.4404 / 316L); FKM; PA; EPDM/X
Materials (wetted parts) stainless steel (1.4305 / 303); ceramics; FKM
Min. pressure cycles 100 million
Tightening torque [Nm] 50; (recommended tightening torque; depends on lubrication, seal and pressure rating)
Process connection threaded connection 1/4" NPT external thread internal thread:M5
Restrictor element integrated no (can be retrofitted)
Remarks
Pack quantity 1 pcs.
Electrical connection
Connection Connector: 1 x M12; coding: A; Contacts: gold-plated