« Back
PX9110 - Pressure transmitter with ceramic measuring cell

PX9110 - Pressure transmitter with ceramic measuring cell

PRODUCENT CODE: PX9110
CATEGORY: Transmitters type PA
Producer: ifm electronic
1130.39 PLN
(net)
7-14 days
The product is available on request
At the moment, the product is not available in our warehouse.
After placing the order, we will notify you of the expected delivery date of the product.
Fast shipping
Free delivery
from 1000 PLN (net)
Do you have questions about the product?
Ask an experienced consultant:
+48 32 237 61 98 w. 101
bn@newtech.com.pl
Description
PA-500PSBN14-B-DVG/US/ /V
  • Reliable detection of system pressure in industrial and mobile applications
  • Precise analogue output
  • With long-term stability thanks to high overload protection
  • Lifespan of more than 100 million pressure cycles
  • High shock and vibration resistance
Technical data
Product characteristics
Number of inputs and outputs Number of analogue outputs: 1
Measuring range [psi] 0...5000
Process connection threaded connection 1/4" NPT external thread internal thread:M5
Application
Special feature Gold-plated contacts
Application for industrial applications
Media liquids and gases
Conditionally suitable for use in gases at pressures &rt; 25 bar only on request
Medium temperature [°C] -25...90
Min. bursting pressure [psi] 17400
Pressure rating [psi] 11600
Type of pressure relative pressure
Electrical data
Operating voltage [V] 16...32 DC
Current consumption [mA] < 18
Min. insulation resistance [MΩ] 100; (500 V DC)
Protection class III
Reverse polarity protection yes
Inputs / outputs
Number of inputs and outputs Number of analogue outputs: 1
Outputs
Total number of outputs 1
Output signal analogue signal
Number of analogue outputs 1
Analogue voltage output [V] 0...10
Min. load resistance [Ω] 2000
Overload protection yes
Measuring/setting range
Measuring range [psi] 0...5000
Accuracy / deviations
Repeatability [% of the span] < 0,15; (with temperature fluctuations < 10 K)
Characteristics deviation [% of the span] < ± 0,35 (BFSL) / < ± 0,75 (LS); (BFSL = Best Fit Straight Line; LS = limit value setting)
Long-term stability [% of the span] < ± 0,05; (per 6 months)
Temperature coefficient zero point [% of the span / 10 K] 0,3; (0...80 °C)
Temperature coefficient span [% of the span / 10 K] 0,4; (0...80 °C)
Response times
Step response time analogue output [ms] 3
Operating conditions
Ambient temperature [°C] -25...80
Storage temperature [°C] -40...100
Protection IP 68; IP 69K
Tests / approvals
EMC
EN 61000-4-2 ESD 4 kV CD / 8 kV AD
EN 61000-4-3 HF radiated 30 V/m
EN 61000-4-4 Burst 2 kV
EN 61000-4-6 HF conducted 10 V
radiation of interference according to the automotive directive 2004/104/EC / CISPR 25
immunity according to the automotive directive 2004/104/EC / ISO 11452-2
HF radiated 100 V/m
pulse resistance ISO 7637-2 / severity level 3
Shock resistance
DIN IEC 68-2-27 50 g (11 ms)
Vibration resistance
DIN IEC 68-2-6 20 g (10...2000 Hz)
MTTF [years] 531
Pressure Equipment Directive Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request
Mechanical data
Weight [g] 207.5
Materials stainless steel (1.4404 / 316L); FKM; PA; EPDM/X
Materials (wetted parts) stainless steel (1.4305 / 303); ceramics; FKM
Min. pressure cycles 100 million
Process connection threaded connection 1/4" NPT external thread internal thread:M5
Restrictor element integrated yes
Remarks
Pack quantity 1 pcs.
Electrical connection
Connection Connector: 1 x M12; coding: A; Contacts: gold-plated