Description
PN-1-1BRBN14-MFRKG/US/ /V
  • Two switching outputs, one of them programmable as analogue output
  • Precise scalable analogue output and high precision over the whole temperature range
  • Clearly visible 4-digit LED display
  • With long-term stability thanks to high overload protection
  • Robust design for use in harsh industrial environments
Technical data
Product characteristics
Number of inputs and outputs Number of digital outputs: 2; Number of analogue outputs: 1
Measuring range -15...15
Process connection threaded connection 1/4" NPT internal thread
Application
Special feature Gold-plated contacts
Application for industrial applications
Media liquids and gases
Medium temperature -25...80
Min. bursting pressure
725 psi5 MPa
Pressure rating
290 psi2 MPa
Type of pressure relative pressure
Electrical data
Operating voltage 18...32 DC; (to SELV/PELV)
Current consumption < 35
Min. insulation resistance 100; (500 V DC)
Protection class III
Reverse polarity protection yes
Power-on delay time 0.3
Integrated watchdog yes
Inputs / outputs
Number of inputs and outputs Number of digital outputs: 2; Number of analogue outputs: 1
Outputs
Total number of outputs 2
Output signal switching signal; analogue signal; (configurable)
Electrical design PNP/NPN
Number of digital outputs 2
Output function normally open / normally closed; (parameterisable)
Max. voltage drop switching output DC 2
Permanent current rating of switching output DC 250
Switching frequency DC < 500
Number of analogue outputs 1
Analogue current output 4...20; (scalable 1:4)
Max. load (Ub - 10 V) / 20 mA
Analogue voltage output 0...10; (scalable 1:4)
Min. load resistance 2000
Short-circuit protection yes
Type of short-circuit protection pulsed
Overload protection yes
Measuring/setting range
Measuring range -15...15
Set point SP -14.8...15
Reset point rP -14.9...14.9
Analogue start point -15...7.5
Analogue end point -7.5...15
In steps of 0.1
Factory setting
SP1 = -7.5 psirP1 = -8.1 psi
SP2 = 7.5 psirP2 = 6.9 psi
ASP = -15 psiAEP = 15 psi
Accuracy / deviations
Switch point accuracy < ± 0,4; (Turn down 1:1)
Repeatability < ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1)
Characteristics deviation < ± 0,25 (BFSL) / < ± 0,5 (LS); (Turn down 1:1; BFSL = Best Fit Straight Line; LS = limit value setting)
Hysteresis deviation < ± 0,1; (Turn down 1:1)
Long-term stability < ± 0,1; (Turn down 1:1; per year)
Temperature coefficient zero point < ± 0,2; (-25...80 °C)
Temperature coefficient span < ± 0,2; (-25...80 °C)
Response times
Response time < 1.5
Damping process value dAP 0.01...4
Damping for the analogue output dAA 0.01...4
Max. response time analogue output 3
Software / programming
Parameter setting options hysteresis / window; normally open / normally closed; switching logic; current/voltage output; Damping; adaptation of displayed values; display can be rotated and switched off; Display unit; zero point; span
Operating conditions
Ambient temperature -25...80
Storage temperature -40...100
Protection IP 65
Tests / approvals
EMC
DIN EN 61000-6-2
DIN EN 61000-6-3
Shock resistance
DIN EN 60068-2-2750 g (11 ms)
Vibration resistance
DIN EN 60068-2-620 g (10...2000 Hz)
MTTF 167.14
Pressure Equipment Directive Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request
Mechanical data
Weight 256.5
Housing cylindrical
Dimensions Ø 34 / L = 91.5
Materials stainless steel (304/1.4301); stainless steel (316L/1.4404); PC; PBT; PEI; FKM; PTFE
Materials (wetted parts) stainless steel (303/1.4305); ceramics; FKM
Min. pressure cycles 100 million
Process connection threaded connection 1/4" NPT internal thread
Restrictor element integrated no (can be retrofitted)
Displays / operating elements
Display
Display unit3 x LED, green
switching status2 x LED, yellow
function displayalphanumeric display, 4-digit
measured valuesalphanumeric display, 4-digit
Display unit mbar; kPa; psi; inH2O; inHg
Remarks
Pack quantity 1 pcs.
Electrical connection
Connection Connector: 1 x M12; coding: A; Contacts: gold-plated