Description
PN-400-SE MFRKG/US/ /
  • Suited for use in homogeniser processes
  • Programmable switching output with IO-Link and scalable analogue output
  • Red/green display for clear identification of the acceptable range
  • The process connection can be rotated for optimum alignment
IO-Link features
  • Convenient operation via buttons or parameter setting via IO-Link
Technical data
Product characteristics
Number of inputs and outputs Number of digital outputs: 2; Number of analogue outputs: 1
Measuring range
0...400 bar 0...5800 psi
Measuring range [MPa] 0...40
Process connection homogeniser connection
Application
Special feature Gold-plated contacts
Measuring element diaphragm seal
Application flush mountable for the food and beverage industry
Media liquids and gases
Medium temperature [°C] 5...90; (for further details see section Diagrams and graphs)
Min. bursting pressure
1000 bar 14500 psi
Min. bursting pressure [MPa] 100
Pressure rating
600 bar 8700 psi
Pressure rating [Mpa] 60
Vacuum resistance [mbar] -1000
Type of pressure relative pressure
Electrical data
Operating voltage [V] 18...30 DC; (to SELV/PELV)
Current consumption [mA] < 35
Min. insulation resistance [MΩ] 100; (500 V DC)
Protection class III
Reverse polarity protection yes
Power-on delay time [s] 0.3
Integrated watchdog yes
Inputs / outputs
Number of inputs and outputs Number of digital outputs: 2; Number of analogue outputs: 1
Outputs
Total number of outputs 2
Output signal switching signal; analogue signal; IO-Link; (configurable)
Electrical design PNP/NPN
Number of digital outputs 2
Output function normally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V] 2
Permanent current rating of switching output DC [mA] 250
Switching frequency DC [Hz] < 500
Number of analogue outputs 1
Analogue current output [mA] 4...20; (scalable 1:5)
Max. load [Ω] 500
Analogue voltage output [V] 0...10; (scalable 1:5)
Min. load resistance [Ω] 2000
Short-circuit protection yes
Type of short-circuit protection pulsed
Overload protection yes
Measuring/setting range
Measuring range
0...400 bar 0...5800 psi
Measuring range [MPa] 0...40
Set point SP
2.5...400 bar 40...5800 psi
Set point SP [MPa] 0.25...40
Reset point rP
1...398.5 bar 10...5780 psi
Reset point rP [MPa] 0.1...39.85
Analogue start point
0...320 bar 0...4640 psi
Analogue start point [MPa] 0...32
Analogue end point
80...400 bar 1160...5800 psi
Analogue end point [MPa] 8...40
In steps of
0.5 bar 10 psi
In steps of [MPa] 0.05
Accuracy / deviations
Switch point accuracy [% of the span] < ± 0,4; (Turn down 1:1)
Repeatability [% of the span] < ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1)
Characteristics deviation [% of the span] < ± 1; (linearity, incl. hysteresis and repeatability; limit value setting to DIN EN IEC 62828-1)
Hysteresis deviation [% of the span] < ± 0,1; (Turn down 1:1)
Long-term stability [% of the span] < ± 0,05; (Turn down 1:1; per 6 months)
Temperature coefficient zero point [% of the span / 10 K] 0,2; (5...80 °C)
Temperature coefficient span [% of the span / 10 K] 0,2; (5...80 °C)
Response times
Response time [ms] < 1.5
Delay time programmable dS, dr [s] 0...50
Damping process value dAP [s] 0...4
Damping for the analogue output dAA [s] 0...4
Max. response time analogue output [ms] 3
Software / programming
Parameter setting options hysteresis / window; normally open / normally closed; switch-on/switch-off delay; Damping; Display unit; current/voltage output
Interfaces
Communication interface IO-Link
Transmission type COM2 (38,4 kBaud)
IO-Link revision 1.1
SDCI standard IEC 61131-9
Profiles Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis
SIO mode yes
Required master port type A
Process data analogue 1
Process data binary 2
Min. process cycle time [ms] 2.3
Supported DeviceIDs
Type of operation DeviceID
default 459
Operating conditions
Ambient temperature [°C] 5...80
Storage temperature [°C] -40...100
Protection IP 67
Tests / approvals
EMC
DIN EN 61000-6-2
DIN EN 61000-6-3
Shock resistance
DIN EN 60068-2-27 50 g (11 ms)
Vibration resistance
DIN EN 60068-2-6 10 g (10...2000 Hz)
Mechanical data
Weight [g] 1479
Materials 1.4542 (17-4 PH / 630); stainless steel (1.4404 / 316L); stainless steel (1.4435 / 316L); PBT+PC-GF30; PBT-GF20; PC
Materials (wetted parts) stainless steel (1.4435 / 316L)
Min. pressure cycles 60 million; (at 1.2 times nominal pressure)
Process connection homogeniser connection
Displays / operating elements
Display
Display unit 3 x LED, green (bar, psi, MPa)
switching status 2 x LED, yellow
measured values alphanumeric display, red/green 4-digit
Remarks
Pack quantity 1 pcs.
Electrical connection