« Back
PY9070 - Pressure sensor with display

PY9070 - Pressure sensor with display

PRODUCENT CODE: PY9070
CATEGORY: Use in homogenizer applications
Producer: ifm electronic
5780.11 PLN
(net)
7-14 days
The product is available on request
At the moment, the product is not available in our warehouse.
After placing the order, we will notify you of the expected delivery date of the product.
Fast shipping
Free delivery
from 1000 PLN (net)
Do you have questions about the product?
Ask an experienced consultant:
+48 32 237 61 98 w. 101
bn@newtech.com.pl
Description
PN-400-SE MFRKG/US/ /
  • Suited for use in homogeniser processes
  • Programmable switching output with IO-Link and scalable analogue output
  • Red/green display for clear identification of the acceptable range
  • The process connection can be rotated for optimum alignment
IO-Link features
  • Convenient operation via buttons or parameter setting via IO-Link
Technical data
Product characteristics
Number of inputs and outputs Number of digital outputs: 2; Number of analogue outputs: 1
Measuring range
0...400 bar 0...5800 psi
Measuring range [MPa] 0...40
Process connection homogeniser connection
Application
Special feature Gold-plated contacts
Measuring element diaphragm seal
Application flush mountable for the food and beverage industry
Media liquids and gases
Medium temperature [°C] 5...90; (for further details see section Diagrams and graphs)
Min. bursting pressure
1000 bar 14500 psi
Min. bursting pressure [MPa] 100
Pressure rating
600 bar 8700 psi
Pressure rating [Mpa] 60
Vacuum resistance [mbar] -1000
Type of pressure relative pressure
Electrical data
Operating voltage [V] 18...30 DC; (to SELV/PELV)
Current consumption [mA] < 35
Min. insulation resistance [MΩ] 100; (500 V DC)
Protection class III
Reverse polarity protection yes
Power-on delay time [s] 0.3
Integrated watchdog yes
Inputs / outputs
Number of inputs and outputs Number of digital outputs: 2; Number of analogue outputs: 1
Outputs
Total number of outputs 2
Output signal switching signal; analogue signal; IO-Link; (configurable)
Electrical design PNP/NPN
Number of digital outputs 2
Output function normally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V] 2
Permanent current rating of switching output DC [mA] 250
Switching frequency DC [Hz] < 500
Number of analogue outputs 1
Analogue current output [mA] 4...20; (scalable 1:5)
Max. load [Ω] 500
Analogue voltage output [V] 0...10; (scalable 1:5)
Min. load resistance [Ω] 2000
Short-circuit protection yes
Type of short-circuit protection pulsed
Overload protection yes
Measuring/setting range
Measuring range
0...400 bar 0...5800 psi
Measuring range [MPa] 0...40
Set point SP
2.5...400 bar 40...5800 psi
Set point SP [MPa] 0.25...40
Reset point rP
1...398.5 bar 10...5780 psi
Reset point rP [MPa] 0.1...39.85
Analogue start point
0...320 bar 0...4640 psi
Analogue start point [MPa] 0...32
Analogue end point
80...400 bar 1160...5800 psi
Analogue end point [MPa] 8...40
In steps of
0.5 bar 10 psi
In steps of [MPa] 0.05
Accuracy / deviations
Switch point accuracy [% of the span] < ± 0,4; (Turn down 1:1)
Repeatability [% of the span] < ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1)
Characteristics deviation [% of the span] < ± 1; (linearity, incl. hysteresis and repeatability; limit value setting to DIN EN IEC 62828-1)
Hysteresis deviation [% of the span] < ± 0,1; (Turn down 1:1)
Long-term stability [% of the span] < ± 0,05; (Turn down 1:1; per 6 months)
Temperature coefficient zero point [% of the span / 10 K] 0,2; (5...80 °C)
Temperature coefficient span [% of the span / 10 K] 0,2; (5...80 °C)
Response times
Response time [ms] < 1.5
Delay time programmable dS, dr [s] 0...50
Damping process value dAP [s] 0...4
Damping for the analogue output dAA [s] 0...4
Max. response time analogue output [ms] 3
Software / programming
Parameter setting options hysteresis / window; normally open / normally closed; switch-on/switch-off delay; Damping; Display unit; current/voltage output
Interfaces
Communication interface IO-Link
Transmission type COM2 (38,4 kBaud)
IO-Link revision 1.1
SDCI standard IEC 61131-9
Profiles Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis
SIO mode yes
Required master port type A
Process data analogue 1
Process data binary 2
Min. process cycle time [ms] 2.3
Supported DeviceIDs
Type of operation DeviceID
default 459
Operating conditions
Ambient temperature [°C] 5...80
Storage temperature [°C] -40...100
Protection IP 67
Tests / approvals
EMC
DIN EN 61000-6-2
DIN EN 61000-6-3
Shock resistance
DIN EN 60068-2-27 50 g (11 ms)
Vibration resistance
DIN EN 60068-2-6 10 g (10...2000 Hz)
Mechanical data
Weight [g] 1479
Materials 1.4542 (17-4 PH / 630); stainless steel (1.4404 / 316L); stainless steel (1.4435 / 316L); PBT+PC-GF30; PBT-GF20; PC
Materials (wetted parts) stainless steel (1.4435 / 316L)
Min. pressure cycles 60 million; (at 1.2 times nominal pressure)
Process connection homogeniser connection
Displays / operating elements
Display
Display unit 3 x LED, green (bar, psi, MPa)
switching status 2 x LED, yellow
measured values alphanumeric display, red/green 4-digit
Remarks
Pack quantity 1 pcs.
Electrical connection