« Back
TA2012 - Temperature transmitter

TA2012 - Temperature transmitter

PRODUCENT CODE: TA2012
CATEGORY: Compact transmitters for the food and beverage industry
Producer: ifm electronic
827.94 PLN
(net)
7-14 days
The product is available on request
At the moment, the product is not available in our warehouse.
After placing the order, we will notify you of the expected delivery date of the product.
Fast shipping
Free delivery
from 1000 PLN (net)
Do you have questions about the product?
Ask an experienced consultant:
+48 32 237 61 98 w. 101
bn@newtech.com.pl
Description
TA-060CLEC34- - /US
  • Hygienic design for the requirements of the food and beverage industry
  • Precise scalable analogue output and high precision over the whole temperature range
  • With diagnostic output for drift and fault monitoring
  • High process safety due to self-monitoring
  • Including free 5-point calibration certificate.
IO-Link features
  • User-friendly communication and parameterisation via IO-Link
Technical data
Product characteristics
Number of inputs and outputs Number of analogue outputs: 1
Measuring range [°C] -50...200
Communication interface IO-Link
Process connection Clamp DN06...DN08 (1/4...3/4") DIN 32676 (ISO 2852)
Installation length EL [mm] 60
Application
Measuring element 1 x Pt 1000; (to DIN EN 60751, class A)
Media liquids and gases
Pressure rating [bar] 100
Vacuum resistance [mbar] -1000
Electrical data
Operating voltage [V] 18...32 DC; ("supply class 2" to cULus)
Current consumption [mA] < 50
Protection class III
Reverse polarity protection yes
Power-on delay time [s] 2
Inputs / outputs
Number of inputs and outputs Number of analogue outputs: 1
Outputs
Total number of outputs 1
Output signal analogue signal; IO-Link; (configurable)
Number of analogue outputs 1
Analogue current output [mA] 4...20
Max. load [Ω] 250; ((18...19 V); 19...32 V: 300 Ω)
Short-circuit protection yes
Overload protection yes
Measuring/setting range
Measuring range [°C] -50...200
Factory setting 0...200 °C
Resolution of analogue output [K] 0.04
Accuracy / deviations
Precision analogue output [K] ± 0,3 + (± 0,1 % MS)
Temperature coefficient [% of the span / 10 K] 0,1; (in case of deviation from the reference condition 25 ± 5 °C)
Response times
Dynamic response T05 / T09 [s] < 0,5 / < 2,0
Interfaces
Communication interface IO-Link
Transmission type COM2 (38,4 kBaud)
IO-Link revision 1.1
Operating conditions
Ambient temperature [°C] -25...80
Note on ambient temperature
at medium temperature: < 160 °C
-25...60 °C
at medium temperature: < 200 °C
Storage temperature [°C] -40...100
Protection IP 67; IP 68; IP 69K
Tests / approvals
EMC
DIN EN 61000-6-2
DIN EN 61000-6-3
Shock resistance
DIN IEC 68-2-27 50 g (11 ms)
Vibration resistance
DIN IEC 68-2-6 10 g (10...2000 Hz)
MTTF [years] 232
Note on approval
factory certificate available as download at www.factory-certificate.ifm
UL approval
UL Approval no. K002
Mechanical data
Weight [g] 112.5
Dimensions [mm] Ø 18.73
Materials stainless steel (1.4404 / 316L); PEI; FKM
Materials (wetted parts) stainless steel (1.4404 / 316L) electropolished
Process connection Clamp DN06...DN08 (1/4...3/4") DIN 32676 (ISO 2852)
Surface characteristics Ra/Rz of the wetted parts Ra: < 0.8
Probe diameter [mm] 6
Installation length EL [mm] 60
Remarks
Remarks
MS = set measuring span
The values for accuracy apply to flowing water.
Pack quantity 1 pcs.
Electrical connection
Connection Connector: 1 x M12; coding: A