TCC241 - Temperature transmitter
PRODUCENT CODE: TCC241
CATEGORY: Self-monitoring transmitters
Producer: ifm electronic
1776.02 PLN
(net)
7-14 days
The product is available on request
At the moment, the product is not available in our warehouse.
After placing the order, we will notify you of the expected delivery date of the product.
At the moment, the product is not available in our warehouse.
After placing the order, we will notify you of the expected delivery date of the product.
Fast shipping
Free delivery
from 1000 PLN (net)
Free delivery
from 1000 PLN (net)
Do you have questions about the product?
Ask an experienced consultant:
Ask an experienced consultant:
Description
TCC150K1ED06-A-DKG/US
- Immediate notification of deviations in accuracy
- Improved quality assurance in between calibration intervals
- Robust design for permanently precise measurements even in demanding environments
- Transparent sensor monitoring thanks to logging of the diagnostic values
- Simulation function simplifies installation
IO-Link features
- Precise analogue output and user-friendly communication via IO-Link
Technical data
Product characteristics | |||||
Number of inputs and outputs | Number of digital outputs: 1; Number of analogue outputs: 1 | ||||
Measuring range |
|
||||
Communication interface | IO-Link | ||||
Process connection | diameter Ø 6 mm | ||||
Installation length EL [mm] | 150 | ||||
Application | |||||
Special feature | Gold-plated contacts | ||||
Measuring element | 1 x Pt 1000 | ||||
Reference element | 1 x NTC | ||||
Media | liquids and gases | ||||
Pressure rating [bar] | 160 | ||||
Electrical data | |||||
Operating voltage [V] | 18...32 DC; ("supply class 2" to cULus) | ||||
Current consumption [mA] | 10; (24 V) | ||||
Protection class | III | ||||
Reverse polarity protection | yes | ||||
Power-on delay time [s] | 6 | ||||
Integrated watchdog | yes | ||||
Inputs / outputs | |||||
Number of inputs and outputs | Number of digital outputs: 1; Number of analogue outputs: 1 | ||||
Outputs | |||||
Total number of outputs | 2 | ||||
Output signal | analogue signal; IO-Link; calibration check status | ||||
Electrical design | PNP/NPN | ||||
Number of digital outputs | 1 | ||||
Output function | normally closed; (diagnostic signal) | ||||
Max. voltage drop switching output DC [V] | 2 | ||||
Permanent current rating of switching output DC [mA] | 100 | ||||
Diagnostic output | calibration check status and error diagnostics | ||||
Number of analogue outputs | 1 | ||||
Analogue current output [mA] | 4...20 | ||||
Max. load [Ω] | (Ub - 15 V) x 50 | ||||
Short-circuit protection | yes | ||||
Type of short-circuit protection | pulsed | ||||
Overload protection | yes | ||||
Measuring/setting range | |||||
Measuring range |
|
||||
Note on measuring range |
|
||||
Factory setting | -10...150 °C / 14...302 °F | ||||
Calibration check limit [K] | 0.5...3 | ||||
In steps of [K] | 0.05 | ||||
Resolution of analogue output [K] | 0.05 | ||||
Accuracy / deviations | |||||
Precision analogue output [K] | ± 0,2 | ||||
Precision IO-Link [K] | ± 0,2 | ||||
Temperature coefficient analogue output [% of the span / 10 K] | < ± 0,02; (in case of deviation from the reference condition 25 ± 5 °C) | ||||
Temperature coefficient IO-Link [% of the span / 10 K] | < ± 0,01; (in case of deviation from the reference condition 25 ± 5 °C) | ||||
Response times | |||||
Dynamic response T05 / T09 [s] | 1,5 / 4 | ||||
Software / programming | |||||
Parameter setting options | Display unit; scaling of the analogue output; calibration check limit; switching logic diagnostic output; simulation mode | ||||
Interfaces | |||||
Communication interface | IO-Link | ||||
Transmission type | COM2 (38,4 kBaud) | ||||
IO-Link revision | 1.1 | ||||
SDCI standard | IEC 61131-9 CDV | ||||
Profiles | Digital Measuring Sensor, Common Profile, Blob Transfer | ||||
SIO mode | yes | ||||
Required master port type | A | ||||
Process data analogue | 1 | ||||
Process data binary | 1 | ||||
Min. process cycle time [ms] | 4.4 | ||||
IO-Link resolution temperature [K] | 0.01 | ||||
Supported DeviceIDs |
|
||||
Operating conditions | |||||
Ambient temperature [°C] | -25...70 | ||||
Note on ambient temperature |
|
||||
Storage temperature [°C] | -40...100 | ||||
Protection | IP 68; IP 69K | ||||
Tests / approvals | |||||
EMC |
|
||||
Shock resistance |
|
||||
Vibration resistance |
|
||||
MTTF [years] | 329 | ||||
Note on approval |
|
||||
UL approval |
|
||||
Mechanical data | |||||
Weight [g] | 374.9 | ||||
Dimensions [mm] | Ø 50 / L = 193.5 | ||||
Materials | stainless steel (1.4404 / 316L); PEI; FKM; PFA | ||||
Materials (wetted parts) | stainless steel (1.4404 / 316L); PEEK | ||||
Process connection | diameter Ø 6 mm | ||||
Surface characteristics Ra/Rz of the wetted parts | Ra: < 0.8 | ||||
Probe diameter [mm] | 6 | ||||
Installation length EL [mm] | 150 | ||||
Remarks | |||||
Remarks |
|
||||
Pack quantity | 1 pcs. | ||||
Electrical connection | |||||
Connection | Connector: 1 x M12; coding: A; Contacts: gold-plated |