TP3233 - Evaluation unit for PT100/PT1000 temperature sensors
PRODUCENT CODE: TP3233
CATEGORY: Temperature plugs
Producer: ifm electronic
439.76 PLN
(net)
7-14 days
The product is available on request
At the moment, the product is not available in our warehouse.
After placing the order, we will notify you of the expected delivery date of the product.
At the moment, the product is not available in our warehouse.
After placing the order, we will notify you of the expected delivery date of the product.
Fast shipping
Free delivery
from 1000 PLN (net)
Free delivery
from 1000 PLN (net)
Do you have questions about the product?
Ask an experienced consultant:
Ask an experienced consultant:
Description
TP- FEC -A-ZVG/US/
- For the signal evaluation of temperature sensors and resistance thermometers
- Reduced mounting complexity and error sources compared to head transmitters
- Automatic recognition of the connected sensor type
- Full potting and robust connection technology for high vibration resistance
IO-Link features
- Precise analogue output and user-friendly communication via IO-Link
Technical data
Product characteristics | |||
Number of inputs and outputs | Number of analogue outputs: 1 | ||
Measuring range |
|
||
Communication interface | IO-Link | ||
Application | |||
Special feature | Gold-plated contacts | ||
Application | for Pt100 and Pt1000 measuring elements | ||
Electrical data | |||
Operating voltage [V] | 20...32 DC | ||
Protection class | III | ||
Reverse polarity protection | yes | ||
Power-on delay time [s] | 1 | ||
Integrated watchdog | yes | ||
Inputs / outputs | |||
Number of inputs and outputs | Number of analogue outputs: 1 | ||
Outputs | |||
Total number of outputs | 1 | ||
Output signal | analogue signal; IO-Link; (configurable) | ||
Number of analogue outputs | 1 | ||
Analogue current output [mA] | 4...20 | ||
Max. load [Ω] | 300 | ||
Short-circuit protection | yes | ||
Type of short-circuit protection | pulsed | ||
Overload protection | yes | ||
Measuring/setting range | |||
Measuring range |
|
||
Factory setting | 0...300 °F | ||
Accuracy / deviations | |||
Precision analogue output [K] | ± 0,3 + (± 0,1 % MS) | ||
Temperature coefficient [% of the span / 10 K] | 0,1 | ||
Response times | |||
Max. measuring/display cycle [ms] | 100 | ||
Interfaces | |||
Communication interface | IO-Link | ||
Transmission type | COM2 (38,4 kBaud) | ||
IO-Link revision | 1.0 | ||
Operating conditions | |||
Ambient temperature [°C] | -25...70 | ||
Storage temperature [°C] | -40...85 | ||
Protection | IP 67 | ||
Tests / approvals | |||
EMC |
|
||
Shock resistance |
|
||
Vibration resistance |
|
||
MTTF [years] | 449 | ||
Mechanical data | |||
Weight [g] | 40.5 | ||
Dimensions [mm] | M12 x 1 | ||
Thread designation | M12 x 1 | ||
Materials | PA; PET | ||
Sealing material | FKM | ||
Remarks | |||
Remarks |
|
||
Pack quantity | 1 pcs. | ||
Electrical connection | |||
Connection | Connector: 1 x M12; coding: A; Moulded body: TPU; Locking: stainless steel (1.4404 / 316L); Sealing: FKM; Contacts: gold-plated |