ESM
Ask an experienced consultant:
Enclosure:
Housing IP30, Terminals IP20
Number of Safety Inputs:
2 Normally Closed
Number of Safety Outputs:
On EM1 Control Unit
Reset Options:
On EM1 Control Unit
Expandability:
Up to 20 Dual Channel Devices
Safety Rating:
CAT4, SIL3, PL-e (When Connected to EM1)
The ESM module gives the option to add additional emergency stop button or 2NC safety device to the EM1 control unit and maintain CAT4 SIL3 PLe performance. The ESM connects via a built in 6-way strap to the adjacent EM1/ESM module. The ESM accepts 2 closed contact inputs from either an emergency stop button or mechanical safety switch (locking or non-locking) Indicator LED’s on the ESM provide diagnostic information along with volt free contact status indicator.
Name | Reference number | Price |
---|---|---|
ESM | 330.006 | - |
Technical Specifications | |
Supply Voltage Options | FROM EM1 |
Power Consumption | NA |
Cable / Connector | SCREW TERMINALS |
Input | 2 NORMALLY CLOSED |
Indication | LED's for Fault, Run, Input 1 and 2 |
Dimensions of Control Unit (mm) | 17.5 x 90 x 58mm |
Weight | NA |
IP Rating | Housing IP30, Terminals IP20 |
Construction | Grey PC-GF |
Mounting | 35mm DIN Rail |
Environmental Specifications | |
Operating Temperature | 0°C to 45°C |
Storage Temperature | -20°C to 60°C |
Safety Related Data | |
PL in accordance with EN ISO 13849-1 | PL-e, CAT 4 |
SIL CL in accordance with EN IEC 62061 | SIL 3 |
PFHd in accordance with EN IEC 62061 | 6.0 x 10 -9 |
PFH | 6.52 x 10 -9 |
B10d | 2,000,000 |
MTTFd | High > 100 Years ( Based on usage rate of 360 Days |
TM | 20 years |
DC | 99% |
SFF | 99.50% |
Notes | |
AS PART OF AN EM1 SYSTEM |