MS5
PRODUCENT CODE: -
CATEGORY: Magnasafe - Magnetic Safety Switches
Producer: Mechan Controls Ltd
Do you have questions about the product?
Ask an experienced consultant:
Ask an experienced consultant:
Description
Housing:
Red ABS, Resin Encapsulated
Contacts:
2NO + 1NC (with door open)
Contact Rating:
300mA 24VDC
Connection Type:
Pre-Wired Cable, 6 cores
Operating Distance:
7mm ON / 17mm OFF
Ingress Protection Rating:
IP67 and IP69K
The MAGNASAFE MS5 are compact, non-contact safety switches designed for use with modern safety relays. Encapsulated into red ABS housings, the MS5 safety switches are easy to install and have a 7 – 17 mm switching distance, making them tolerant to misalignment and helping to ensure a long and trouble free operating life.
Models
Name | Reference number | Price |
---|---|---|
MS5-21-DC-01M | 354.075 | - |
MS5-21-DC-03M | 354.050 | - |
MS5-21-DC-03M(SO) | 354.069 | - |
MS5-21-DC-05M | 354.059 | - |
MS5-21-DC-06M | 354.062 | - |
MS5-21-DC-10M | 354.061 | - |
MS5-ACT | 354.053 | - |
Technical data
Technical Specifications | |
Construction | Red ABS, Resin Filled |
Indication | 1 x Volt Free Contact |
IP Rating | IP67 / IP69K |
Weight | na |
Mounting | 4 x M4 Security Screws |
Safety Output | Up to 2 x NO |
Safety Output Rating | 24Vdc / 300mA |
Auxilliary Output | Up to 1 x NC |
Auxilliary Output Rating | 15W / 10VA |
Cable / Connector | Pre-wired |
Cable Length | 3, 6 or 10 metre |
Coding | Magnet & Reed |
Dimensions of Switch (mm) | 52 x 28 x 14mm |
Dimensions of Actuator (mm) | 52 x 28 x 14mm |
Environmental Specifications | |
Operating Temperature | -25°C to 55°C |
Storage Temperature | -20°C to 60°C |
Safety Related Data | |
PL in accordance with EN ISO 13849-1 | na |
SIL CL in accordance with EN IEC 62061 | na |
PFHd in accordance with EN IEC 62061 | 4.3 x 10-8 See Note 1 |
PFH | 6.52 x 10-8 |
B10d | 2,000,000 |
MTTFd | High > 100 Years ( Based on usage rate of 360 Days |
TM | > 20 Years |
DC | 99% |
SFF | 98% |
Notes | |
Based on dual channel wiring according to CAT 4. Diagnostic coverage provided by downstream control logic. DC - medium, MTTFd = 100 Years |