MS5LQD
Ask an experienced consultant:
Housing:
Red ABS, Resin Encapsulated
Contacts:
2NO, 2NO + 1NC (with door open)
Contact Rating:
300mA 24VDC
Connection Type:
M12, 4-Pole / 6-Pole
Operating Distance:
7mm ON / 17mm OFF
Ingress Protection Rating:
IP67 and (IP69K: Pre-Wired Only)
The MAGNASAFE MS5 LQD are compact, non-contact safety switches designed for use with modern safety relays. Encapsulated into red ABS housings, the MS5 safety switches are easy to install, tolerant to misalignment. The non-contact operation has an 7 – 17 mm switching distance helping to ensure a long and trouble free operating life. The LQD version has 150mm connecting cable with M12, 6 pole connector, and can be supplied with 5 or 10 metre matching cable.
Name | Reference number | Price |
---|---|---|
4-CORE-1KEYWAY-05M-QD | 356.071 | - |
4-CORE-1KEYWAY-10M-QD | 356.072 | - |
6-CORE-2KEYWAY-05M-QD | 360.004 | - |
6-CORE-2KEYWAY-10M-QD | 360.012 | - |
MS5-20-DC-LQD | 354.064 | - |
MS5-21-DC-LQD | 354.056 | - |
Technical Specifications | |
Construction | Red ABS, Resin Filled |
Indication | 1 x Volt Free Contact |
IP Rating | IP67 |
Weight | na |
Mounting | 4 x M4 Security Screws |
Safety Output | Up to 2 x NO |
Safety Output Rating | 24Vdc / 300mA |
Auxilliary Output | Up to 1 x NC |
Auxilliary Output Rating | 15W / 10VA |
Cable / Connector | Leaded Quick Disconnect |
Cable Length | 5 or 10 metre |
Coding | Magnet & Reed |
Dimensions of Switch (mm) | 52 x 28 x 14mm |
Dimensions of Actuator (mm) | 52 x 28 x 14mm |
Environmental Specifications | |
Operating Temperature | -25°C to 55°C |
Storage Temperature | -20°C to 60°C |
Safety Related Data | |
PL in accordance with EN ISO 13849-1 | na |
SIL CL in accordance with EN IEC 62061 | na |
PFHd in accordance with EN IEC 62061 | 4.3 x 10-8 See Note 1 |
PFH | 6.52 x 10-8 |
B10d | 2,000,000 |
MTTFd | High > 100 Years ( Based on usage rate of 360 Days |
TM | > 20 Years |
DC | 99% |
SFF | 98% |
Notes | |
Based on dual channel wiring according to CAT 4. Diagnostic coverage provided by downstream control logic. DC - medium, MTTFd = 100 Years |