MS6SSQD
Ask an experienced consultant:
Housing:
316 Stainless Steel, Resin Encapsulated
Contacts:
1NO, 1NO + 1NC, 2NO, 2NO + 1NC (with door open)
Contact Rating:
2Amp 230VAC / 1Amp 24VDC
Connection Type:
M12, 4-Pole / 6-Pole
Operating Distance:
10mm ON / 28mm OFF
Ingress Protection Rating:
IP67 and IP69K (pre-wired only)
The MAGNASAFE MS6 non-contact safety switches are an industry standard, slim-line, space saving design. Encapsulated into red ABS housings, the MS6 safety switches are easy to install, tolerant to misalignment. The non-contact operation has an 10 – 28 mm switching distance helping to ensure a long and trouble free operating life.
Name | Reference number | Price |
---|---|---|
MS6-SS-10-AC-QD(NC) | 356.054 | - |
MS6-SS-10-AC-QD-05M | 356.055 | - |
MS6-SS-11-DC-QD(NC) | 356.064 | - |
MS6-SS-11-DC-QD-05M | 356.065 | - |
MS6-SS-20-DC-QD(NC) | 356.075 | - |
MS6-SS-20-DC-QD-05M | 356.076 | - |
MS6-SS-21-DC-QD(NC) | 356.069 | - |
Technical Specifications | |
Safety Output | Up to 2 x NO |
Safety Output Rating | 230Vac / 2Amps or 24Vdc / 1 Amp |
Auxilliary Output | Up to 1 x NC |
Auxilliary Output Rating | 15W / 10VA |
Cable / Connector | Quick disconnect |
Cable Length | 5 or 10 metre |
Coding | Magnet & Reed |
Dimensions of Switch (mm) | 81.5 x 19 x 19mm |
Dimensions of Actuator (mm) | 81.5 x 19 x 19mm |
Weight | na |
IP Rating | IP67 |
Construction | 316 Grade Stainless Steel |
Mounting | 4 x M4 Security Screws |
Environmental Specifications | |
Operating Temperature | -25°C to +55°C |
Storage Temperature | -25°C to +55°C |
Safety Related Data | |
PL in accordance with EN ISO 13849-1 | na |
SIL CL in accordance with EN IEC 62061 | na |
PFHd in accordance with EN IEC 62061 | 4.3 x 10-8 See Note 1 |
PFH | 6.52 x 10-8 |
B10d | 2,000,000 |
MTTFd | High > 100 Years ( Based on usage rate of 360 Days |
TM | > 20 Years |
DC | 99% |
SFF | 98% |
Notes | |
Based on dual channel wiring according to CAT 4. Diagnostic coverage provided by downstream control logic. DC - medium, MTTFd = 100 Years |