RSSG
Ask an experienced consultant:
Housing:
Orange ABS, Resin Encapsulated
Contacts:
2NO + 1NC (with door open)
Contact Rating:
3A - 24Vdc & 230Vac
Coding:
Uniquely Coded, RFID
Indication:
Bi-Colour LED (Open/Close Indication)
Ingress Protection Rating:
IP67 and IP69K
RSSG are standalone, non-contact RFID safety switches. With 2NO + 1NC contacts, capable of switching 3A at 24Vdc & 230Vac. With tamper proof RFID switching, the RSSG is suitable for use with most safety relays. A dual colour, built in LED helps the operator in speedy fault diagnosis. The RSSR safety switches are available with 3, 6 or 10 metre pre-wired cables which are fully sealed and suitable for use in most wet / harsh environments.
Name | Reference number | Price |
---|---|---|
RSSG-21-DC-03M | 364.020 | - |
RSSG-21-DC-06M | 364.021 | - |
RSSG-21-DC-10M | 364.022 | - |
RSSG-ACT | 364.035 | - |
Technical Specifications | |
Supply Voltage Options | 24Vdc |
Power Consumption | 2VA / 2W |
Safety Output | 2 X NO |
Safety Output Rating | 24Vdc/230Vac / 3 Amps |
Auxilliary Output | 1 X NC |
Auxilliary Output Rating | 24Vdc/230Vac / 3 Amps |
Cable / Connector | PRE-WIRED |
Cable Length | 3, 6 or 10 metre |
Coding | RFID, Uniquely coded |
Indication | DUAL COLOUR LED |
Dimensions of Switch (mm) | 88 X 25 X 20 |
Dimensions of Actuator (mm) | 88 X 25 X 20 |
IP Rating | IP67 / IP69K |
Construction | ORANGE ABS, RESIN FILLED |
Mounting | 4 x M4 Security Screws |
Environmental Specifications | |
Operating Temperature | -25°C to +60°C |
Storage Temperature | -10°C to +60°C |
Safety Related Data | |
PL in accordance with EN ISO 13849-1 | E |
SIL CL in accordance with EN IEC 62061 | 3 |
PFHd in accordance with EN IEC 62061 | 4.3 x 10-8 |
PFH | 6.52 x 10-8 |
B10d | 2,000,000 |
MTTFd | High > 100 Years ( Based on usage rate of 360 Days |
TM | > 20 Years |
DC | 99% |
SFF | 99% |
Notes | |
1) Based on dual channel wiring according to CAT 4. Diagnostic coverage provided by downstream control logic. DC - medium, MTTFd = 100 Years |