« Back
RSSG SS LQD

RSSG SS LQD

PRODUCENT CODE: -
CATEGORY: RSS-Series - RFID Safety Switches
Producer: Mechan Controls Ltd
Do you have questions about the product?
Ask an experienced consultant:
+48 694 467 166
bs@newtech.com.pl
Description

Housing:
    316 Stainless Steel, Resin Encapsulated
Contacts:
    2NO + 1NC (with door open)
Connection:
    M12, 8-Pole
Coding:
    Uniquely Coded, RFID
Indication:
    Bi-Colour LED (Open/Close Indication)
Ingress Protection Rating:
    IP67 and (IP69K: Pre-Wired Only)

RSSG-SS are standalone, non-contact RFID safety switches. With 2NO + 1NC contacts, capable of switching 500mA at 24Vdc. With tamper proof RFID switching, the RSSG-SS are suitable for use with safety relays with a low inrush current. A dual colour, built in LED helps the operator in speedy fault diagnosis. The RSSG-SS safety switches are available with an M12 leaded quick disconnect which are fully sealed and suitable for use in most wet / harsh environments

To view our animated video, please follow the link: RSSG-SS Video

Models
Name Reference number Price
8-CORE-1KEYWAY-05M-QD 356.073 -
8-CORE-1KEYWAY-10M-QD 356.077 -
RSSG-SS-21-DC-LQD 364.031 -
RSSG-SS-21-DC-LQD-05M 364.032 -
RSSG-SS-21-DC-LQD-10M 364.033 -
RSSG-SS-ACT 364.034 -
Technical data
Technical Specifications
Supply Voltage Options 24VDC
Power Consumption 2VA / 2W
Safety Output 2 X NO
Safety Output Rating 24Vdc/230Vac / 500mA
Auxilliary Output 1 X NC
Auxilliary Output Rating 24Vdc/230Vac / 500mA
Cable / Connector M12 Quick Disconnect
Cable Length 150mm
Coding RFID, Uniquely coded
Indication DUAL COLOUR LED
Dimensions of Control Unit (mm)
Dimensions of Switch (mm) 88 X 25 X 20
Dimensions of Actuator (mm) 88 X 25 X 20
IP Rating SWITCH (IP69K) CONNECTOR (IP67)
Construction 316 Stainless Steel
Mounting 4 x M4 Security Screws
Environmental Specifications
Operating Temperature -25°C to +60°C
Storage Temperature -10°C to +60°C
Safety Related Data
PL in accordance with EN ISO 13849-1 E
SIL CL in accordance with EN IEC 62061 3
PFHd in accordance with EN IEC 62061 4.3 x 10-8
PFH 6.52 x 10-8
B10d 2,000,000
MTTFd High > 100 Years (Based on usage rate of 360 Days)
TM > 20 Years
DC 99%
SFF 99%
Notes

1) Based on dual channel wiring according to CAT 4. Diagnostic coverage provided by downstream control logic. DC - medium, MTTFd = 100 Years