« Back
SSC

SSC

PRODUCENT CODE: -
CATEGORY: S-Type - RFID Safety Switches
Producer: Mechan Controls Ltd
Do you have questions about the product?
Ask an experienced consultant:
+48 694 467 166
bs@newtech.com.pl
Description

Housing:
    Blue ABS, Resin Encapsulated
Contacts:
    1NO + 1NC or 2NO (with door open)
Contact Rating:
    500mA 24VDC
Coding:
    Single Code, RFID
Indication:
    Guard Status Indication
Ingress Protection Rating:
    IP67 and IP69K

SS-C safety switches are standalone RFID, non-contact, safety switches. With 2NO or 1NO + 1NC contacts, capable of switching 500mA at 24Vdc or 110Vac.

With tamper resistant, RFID switching, the SS-C are suitable for use with most modern, low inrush current, safety relays. A dual colour, built in LED, helps the operator in speedy fault diagnosis. The SS-C safety switches are available with 3, 5 or 10 metre pre-wired cables which are fully sealed and suitable for use in most wet / harsh environments.

Models
Name Reference number Price
SS-C-11-03M 363.002 -
SS-C-11-05M 363.000 -
SS-C-11-10M 363.001 -
SS-C-20-03M 363.005 -
SS-C-ACT 363.099 -
Technical data
Technical Specifications
Supply Voltage Options 24VDC
Power Consumption na
Safety Output Up to 2 x NO
Safety Output Rating 110Vac / 500mA or 24Vdc / 500mA
Auxilliary Output Up to 1 x NC
Auxilliary Output Rating 110Vac / 500mA or 24Vdc / 500mA
Cable / Connector Pre-wired
Cable Length 3, 5 or 10 metre
Coding RFID, Generic code
Indication DUAL COLOUR LED
Dimensions of Switch (mm) 82.5 x 19 x 17mm
Dimensions of Actuator (mm) 82.5 x 19 x 19mm
Weight na
IP Rating IP67 / IP69K
Construction Blue ABS, Resin Filled
Mounting 4 x M4 Security Screws
Environmental Specifications
Operating Temperature -25°C to +55°C
Storage Temperature -25°C to +55°C
Safety Related Data
PL in accordance with EN ISO 13849-1 na
SIL CL in accordance with EN IEC 62061 na
PFHd in accordance with EN IEC 62061 4.3 x 10-8 See Note 1
PFH 6.52 x 10-8
B10d 2,000,000
MTTFd High > 100 Years ( Based on usage rate of 360 Days
TM > 20 Years
DC 99%
SFF 99%
Notes

1)
Based on dual channel wiring according to CAT 4. Diagnostic coverage provided by downstream control logic. DC - medium, MTTFd = 100 Years