Housing:
    Blue ABS, Resin Encapsulated
Contacts:
    2NO + 1NC (with door open)
Contact Rating:
     2A - 24Vdc & 230Vac
Coding:
    Single Code, RFID
Indication:
    Guard Status Indication
Ingress Protection Rating:
    IP67 and IP69K

The SS-R are standalone RFID, non-contact, safety switches. With 2NO + 1NC contacts, capable of switching 2A at 30Vdc or 230Vac.

With tamper resistant, RFID switching, the SS-R are suitable for use with most safety relays. A dual colour, built in LED, helps the operator in speedy fault diagnosis. The SS-R safety switches are available with 3, 5, 6, 10 or 15 metre pre-wired cables which are fully sealed and suitable for use in most wet / harsh environments.

Models
Name Reference number Price
SS-R-21-03M 362.000 -
SS-R-21-05M 362.004 -
SS-R-21-06M 362.005 -
SS-R-21-10M 362.001 -
SS-R-21-15M 362.006 -
SS-R-ACT 362.099 -
Technical data
Technical Specifications
Supply Voltage Options 24VDC
Power Consumption na
Safety Output Up to 2 x NO
Safety Output Rating 230Vac / 2A or 30Vdc / 2A
Auxilliary Output Up to 1 x NC
Auxilliary Output Rating 230Vac / 2A or 30Vdc / 2A
Cable / Connector Pre-wired
Cable Length 3, 5, 6 10 or 15 metre
Coding Electronic, Generic code
Indication DUAL COLOUR LED
Dimensions of Switch (mm) 92 x 24.5 x 23mm
Dimensions of Actuator (mm) 92 x 23 x 18mm
Weight na
IP Rating IP67 / IP69K
Construction Blue ABS, Resin Filled
Mounting 4 x M4 Security Screws
Environmental Specifications
Operating Temperature -25°C to +55°C
Storage Temperature -25°C to +55°C
Safety Related Data
PL in accordance with EN ISO 13849-1 na
SIL CL in accordance with EN IEC 62061 na
PFHd in accordance with EN IEC 62061 4.3 x 10-8 See Note 1
PFH 6.52 x 10-8
B10d 2,000,000
MTTFd High > 100 Years ( Based on usage rate of 360 Days
TM > 20 Years
DC 99%
SFF 99%
Notes

1)
Based on dual channel wiring according to CAT 4. Diagnostic coverage provided by downstream control logic. DC - medium, MTTFd = 100 Years