« Back
Absolute encoder AV3650M

Absolute encoder AV3650M

PRODUCENT CODE: -
CATEGORY: Absolute rotary encoders
Producer: SIKO GmbH
The product is available on request
At the moment, the product is not available in our warehouse.
After placing the order, we will notify you of the expected delivery date of the product.
Fast shipping
Free delivery
from 1000 PLN (net)
Do you have questions about the product?
Ask an experienced consultant:
+48 32 237 61 98 w. 117
rw@newtech.com.pl
Description
The AV3650M rotary encoder is an absolute magnetic single- and multi-turn rotary encoder, which impresses with its extremely compact design. It is particularly robust and resistant to vibrations.  Thanks to its high protection class up to IP67 and a temperature range of -40° C … +85° C, it is also suitable for demanding industrial applications. The particularly small design with a diameter of only 36 mm predestines the rotary encoder for use in applications with limited installation space. The analog current or voltage outputs can be adjusted to any measuring range thanks to the teach-in.
  • Absolute wear-free magnetic encoder
  • Multiturn without gearbox and without battery
  • Current or voltage output interfaces
  • Extremely compact and very robust design
  • IP67 protection class
  • Extensive temperature range -40 … 85° C
  • Optimal price-performance ratio
Technical data
Mechanical data
Shaft rustproof stainless steel
Flange aluminum
Housing zinc die-casting
Speed 6000 rpm (at protection class IP65 with mounting type M3, M4, transient for ≤10 min)
3000 rpm (at protection class IP65 with mounting type M3, M4, continuous operation)
4000 rpm (at protection class IP67 or mounting type M1, M2, transient for ≤10 min)
2000 rpm (at protection class IP67 or mounting type M1, M2, continuous operation)
Starting torque <0.007 Nm at 20 °C (at protection class IP65 with mounting type M3, M4)
<0.01 Nm at 20 °C (at protection class IP67 with mounting type M3, M4)
<0.01 Nm at 20 °C (at mounting type M1, M2)
Shaft load rating 40 N (radial, mounting type M3, M4)
20 N (axial, mounting type M3, M4)
80 N (radial, mounting type M1, M2)
40 N (axial, mounting type M1, M2)
Cable sheath PVC (ø6.2 ±0.2 mm)
Cable bending radius 60 mm (static)
130 mm (dynamic)
Mounting type clamping flange joint ø58 mm (mounting type M1)
servo flange ø58 mm (mounting type M2)
clamping flange joint ø36 mm (mounting type M3)
servo flange ø36 mm (mounting type M4)
Weight ~0.2 kg
Electrical data
Operating voltage 10 … 30 V DC (at output 0 ... 5 V, reverse polarity protected, power supply unit corresponds to Class 2 (UL 1310))
15 … 30 V DC (at output 0 ... 10 V, reverse polarity protected, power supply unit corresponds to Class 2 (UL 1310))
10 … 30 V DC (at output 4 ... 20 mA, but UB > Uload +2.0 V, reverse polarity protected, power supply unit corresponds to Class 2 (UL 1310))
Current consumption ≤30 mA (without load)
Parameter storage 104 cycles (also applies to calibration operations)
Inputs 2 (limit inputs, high active)
Input signal level high +UB (≥1 s)
Status display two-color LED (red/green) (device status)
Output voltage 0 … 5 V (load ≥500 Ω)
0 … 10 V (load ≥1000 Ω)
Output current 4 … 20 mA (load ≤900 Ω, at 24 V DC)
Temperature drift <100 ppm/K
Cycle time 1 ms
Starting time <1 s
Settling time <1 ms (at output 0 ... 5 V and 0 ... 10 V, load = 1000 Ω, 25° C)
<1 ms (at output 4 ... 20 mA, load = 900 Ω, 25° C)
Type of connection 1x M12 connector (A-coded) (5-pole, 1x pin, E12E connection type)
open cable end (E1 connection type)
System data
Scanning magnetic
Resolution 11 bit (at 0 ... 5 V, analog output FS)
12 bit (at 0 ... 10 V, 4 ... 20 mA, analog output FS)
System accuracy ±1°
Repeat accuracy ±0.2°
Measuring range ≥22.5°
65536 revolution(s) (16 bit, factory setting 16 rotation(s))
Approval UL (UL 61010-1, File No. E503367)
Ambient conditions
Ambient temperature -40 … 85 °C
Storage temperature -40 … 85 °C
Relative humidity 93 % (condensation inadmissible)
EMC DIN EN 61326-1 (immunity requirement of industry)
DIN EN 61000-4-2, -3, -6, -8 (interference resistance / immission)
DIN EN 61000-4-4, -5 (burst / surge)
DIN EN 61000-6-4 (emitted interference / emission)
DIN EN 55011 Class B (radiation emission / radio interference suppression)
Safety regulations UL 61010-1 (Indoor use, outdoor use possible, not intended for use involving direct exposure to UV light.
Environment dry / wet.
Protection class III as per EN 61140.
Pollution degree 2 as per EN 61010.
Maximum humidity 93% at 40 °C.)
Protection category IP65 (EN 60529 (protection type not yet reviewed by UL))
IP67 (EN 60529 (protection type not yet reviewed by UL))
Shock resistance 2500 m/s2, 6 ms (EN 60068-2-27)
Vibration resistance 300 m/s2, 10 … 2000 Hz (EN 60068-2-6)