« Back
Draw-Wire Encoder SGH10L

Draw-Wire Encoder SGH10L

PRODUCENT CODE: -
CATEGORY: Position sensors for hydraulic cylinders
Producer: SIKO GmbH
The product is available on request
At the moment, the product is not available in our warehouse.
After placing the order, we will notify you of the expected delivery date of the product.
Fast shipping
Free delivery
from 1000 PLN (net)
Do you have questions about the product?
Ask an experienced consultant:
+48 32 237 61 98 w. 117
rw@newtech.com.pl
Description
The SGH10 wire-actuated encoder measures the absolute direct cylinder stroke in a hydraulic cylinder. The new measuring system eliminates costly boring of the piston. As a result, integration costs are reduced compared to other measuring systems and a possible weakening of the piston is avoided effectively. The highlight of the SGH10L: Thanks to its unique lateral installation, the SGH10L can also be used in almost unsolvable applications, regardless of whether for applications in which no stoke lost can be accepted, extremely small piston diameters or in the case of cylinders with mechanical end position cushioning.
  • Measuring range 0 … 1000 mm (39.37 inches)
  • almost no stoke lost thanks to lateral mounting
  • Absolute measuring system
  • CANopen interface, analog: Current and voltage
  • Operating voltage 9 ... 32 VDC
  • Pressure-resistant up to 350 bar, pressure peaks up to 450 bar
  • High degree of flexibility, adjustable to all measuring lengths thanks to teach-in 
  • High electro-magnetic compatibility
  • High shock and vibration resistance
  • With PURE.MOBILE technology
Technical data
Mechanical data
Housing stainless steel (V4A housing, 1.4404 uncoated)
steel (St housing, 1.7225 not coated)
seal HNBR (Sensor)
Viton (Screw-in connector housing V4A)
NBR (Screw-in connector housing St)
Wire design ø0.45 mm (rustproof stainless steel)
Extension force ≥2 N
Acceleration ≤10 m/s2
Weight ~2.1 kg (V4A housing without spacer tube)
~2 kg (St housing without spacer tube)
Electrical data
Operating voltage 9 … 32 V DC (with output 0 ... 5 V, 0.5 ... 4.5 V, 0.25 ... 4.75 V, 1.0 ... 4.9 V, reverse polarity protected)
12 … 32 V DC (with output 0 … 10 V, reverse polarity protected)
12 … 32 V DC (with output 0 ... 20 mA, but UB > Uload +2.0 V, 4 ... 20 mA, reverse polarity protected)
Current consumption <32 mA (without load)
Power input <0.5 W (without load)
Digital inputs 2 (limit inputs)
Input signal level high >8.4 V
Input signal level low <2.8 V
Output voltage 0 … 10 V (load current <1 mA)
0 … 5 V (load current <1 mA)
0.5 … 4.5 V (load current <1 mA)
0.25 … 4.75 V (load current <1 mA)
1 … 4.9 V (load current <1 mA)
Output current 0 … 20 mA (load ≤500 Ω)
4 … 20 mA (load ≤500 Ω)
Linearity tolerance ±0.25 % (1000 mm measuring length, ±0.5% output value range ≤15 mV)
±0.5 % (500 mm measurement length)
Settling time <150 ms
Type of connection 1x M12 plug connector (A-coded) (5-pole, 1x pin)
Operating voltage 10 … 30 V DC (reverse polarity protected)
Power input <0.8 W
Parameter storage 105 cycles (also applies to calibration operations)
Linearity tolerance ±0.25 % (1000 mm measurement length)
±0.5 % (500 mm measurement length)
Interface according to ISO 11898, not isolated (CANopen, CiA 301, CiA 305, CiA 406)
Address 1 … 127 (Node-ID, per SDO or Layer Setting Service (LSS))
Baud rate ≤1 Mbit/s
Cycle time typical 1.5 ms
Settling time <150 ms
Type of connection 1x M12 plug connector (A-coded) (5-pole, 1x pin)
System data
Scanning magnetic
Resolution 12 bit (analog output)
Repeat accuracy ±0.15 mm
Measuring range 500 mm (measuring range flexibly usable between 0 ... 500 mm)
1000 mm (measuring range flexibly usable between 0 ... 1000 mm)
Travel speed ≤1 m/s
Failure rate 235.6 year(s) (analog output, at 60 °C (MTBF)
EN/IEC 61709 (SN 29500))
253.3 year(s) (CANopen, at 60 °C (MTBF)
EN/IEC 61709 (SN 29500))
Approval E1 compliant (UN ECE R10 Approval number:
E1 10 R - 05 8507)
Ambient conditions
Ambient temperature -40 … 105 °C (electronics)
-30 … 105 °C (mechanics)
Storage temperature -40 … 85 °C
Relative humidity 100 % (condensation admissible in the mounted and plugged condition)
Operating pressure <350 bar (Pn based on ISO19879)
Overload pressure <450 bar (Pmax based on ISO 19879)
Test pressure 650 bar (Pstatic based on ISO 19879)
EMC EN 61326-3.1 (immunity requirement of industry, class B emission limit)
ISO 11452-1, -2, -3, -4, -5 (interference radiation ESA)
ISO 7637-1, -2 (transient pulses)
ISO 10605 (electrostatic discharge (ESD))
Protection category IP6K9K (ISO 20653, fitted with suitable mating connector)
Shock resistance 1000 m/s2, 11 ms (EN 60068-2-27, additional support is recommended)
Vibration resistance 70 m/s2, 10 Hz … 2 kHz (EN 60068-2-64, additional support is recommended at >150 Hz)