Description
Display accuracy max. 10 μm
- Repeat accuracy max. ±0.01 mm
- High-contrast LCD, 12-digit LCD dot matrix
- Incremental measurement and calibration function
- Direct reference/offset value input
- Calibration input
- Works with sensor MSA
- Option: serial interface RS232/RS485
- Option: TG01 bench housing
Technical data
Mechanical data | |
Housing design | built-in housing, plastic (switchboard cutout 92+0.8 x 45+0.6 IEC 61554) |
Electrical data | |
Operating voltage | 24 V DC ±20 % 115 V AC ±10 % 230 V AC ±10 % |
Current consumption | 70 mA (at 24 V DC) 20 mA (at 115 V AC) 10 mA (at 230 V AC) |
Display/display range | 12-digit, LCD dot matrix, backlit (-9999999 ... 9999999, arithmetic signs, units) |
Switching outputs | with or without (2x 30 V ≤100 mA) |
Interface | without, RS232, RS485 |
Type of connection | connector (9-pole, (supply, switching output, interface/calibration input)) mini-DIN (8-pole, 1x socket (MSA sensor)) |
System data | |
Resolution | 0.01, 0.1, 1, 10 mm (programmable angle display) 0.001, 0.01, 0.1, 1 in |
System accuracy | ±(0.05 + 0.03 x L) mm; L in m (at TU = 20 °C) |
Repeat accuracy | ±0.01 mm (±1 increment) |
Travel speed | ≤5 m/s |
Ambient conditions | |
Ambient temperature | 0 … 50 °C |
Storage temperature | -20 … 80 °C |
Relative humidity | ≤95 % (condensation inadmissible) |
EMC | EN 61000-6-2 (interference resistance / immission) EN 61000-6-4 (emitted interference / emission) |
Protection category | IP40 whole device (EN 60529) IP60 at the front with switchboard installation (EN 60529) |