Description
The AP10 position indicator with communication interface is used for monitored format adjustment to reduce setup times and increase machine efficiency. Readability is optimized for intuitive user prompting: The backlit display clearly shows the setpoint and actual value, and the two LEDs clearly indicate the direction in which the adjustment must be made. The IO link interface enables easy and reliable integration into modular machines.
  • Electronic position indicator with interface
  • Stainless-steel hollow shaft ø20 mm, up to ø25.4 mm as an option
  • Backlit display
  • Two-line LCD for target and actual values
  • Reset, incremental measurement, offset via keyboard
  • Integrated RS485 interface, CAN bus or IO-Link as an option
  • Robust sensor technology unit thanks to magnetic scanning
  • User guidance through status LEDs
  • Mechanically compatible with the DA09S position indicator
  • IP53 protection class, IP65 as an option
  • Industry 4.0 ready
Technical data
Mechanical data
Shaft stainless steel
Housing reinforced plastic (plug thread, nickel-plated brass/cover, metal ground connection)
Color black, RAL 9005
Speed ≤500 rpm
Weight ~0.2 kg
Electrical data
Operating voltage 24 V DC ±20 %
Current consumption ~30 mA (additional ~3 mA per LED when operated with LEDs)
Power input ~0.72 VA (Max. power supply of the power supply unit used: 100 VA.
The power supply used corresponds to SELV/Limited Energy (IEC 61010-1) or SELV/LPS (IEC 60950-1) or Class 2 (UL 1310).)
Battery service life ~8 year(s)
Parameter storage 105 cycles (also applies to calibration operations)
Display/display range 6-digit LCD 14-segment, ~8 mm height (decimal points, 2 rows, special characters (backlit LED red/white))
Special character cw arrow, ccw arrow, incremental measurement, battery
Status display 2x two-color LED (red/green) (position status, configurable)
Keys incremental measurement function, parameterizing, resetting
Interface RS485; CANopen; IO Link (no galvanic isolation)
Type of connection 2x M8-plug connectors (A-coded) (4-pin, 1x socket, 1x pin (RS485, CANopen))
1x M8 connector (A-coded) (4-pin, 1x pin (IO-Link))
grounding via flat male tab 6.3 mm or terminal lug
System data
Scanning magnetic
Resolution 880 increments/revolution (displayed value/rotation freely configurable)
Measuring range ≤190650 revolution(s)
Approval UL (UL 61010-1, File No. E503367)
Ambient conditions
Ambient temperature 0 … 60 °C
Storage temperature -20 … 80 °C
Relative humidity condensation inadmissible
EMC EN 61326-1 (Industry immunity requirement, class B emission limit, shielded line required)
Safety regulations DIN EN 61010-1 (VDE 0411-1), UL 61010-1 (Limited power supply according to DIN EN 61010-1 Section 9.4.
Protection class II
Surge category II
Pollution level 2)
Protection category IP53 (EN 60529, only with mating connector (protection class not examined by UL))
IP65 (EN 60529, only with mating connector (protection class not examined by UL))
Shock resistance 500 m/s2, 11 ms (EN 60068-2-27)