Description
- Repeat accuracy max. ±1 μm
- Status LED display
Works with MB100/1 magnetic tape
Works with MBR100 magnetic tape ring
- Reading distance ≤0.4 mm
- Signal period 1000 μm
- Output circuit sin/cos 1 VSS
- Robust metal housing
Technical data
Mechanical data | |
Housing | zinc die-cast/aluminum (M design) zinc die-cast (ZM design) |
Sensor/band reading distance | 0.1 … 0.4 mm (reference signal O, IA, ID) 0.1 … 0.2 mm (reference signal RB, RD) |
Sensor/ring reading distance | 0.1 … 0.4 mm (reference signal O, IA, ID) 0.1 … 0.2 mm (reference signal RB, RD) |
Cable sheath | PUR, suitable for drag-chain use (6, 8-wire ø5-0.4 mm) |
Cable bending radius | 5x cable diameter (static) 7.5x cable diameter (dynamic) |
Service life of cable | >5 million cycles (under the following test conditions: travel range 4.5 m travel speed 3 m/s acceleration 5 m/s2 ambient temperature 20 °C ±5 °C) |
Electrical data | |
Operating voltage | 10.5 … 30 V DC (reverse polarity protected) 5 V DC ±5 % (no reverse polarity protection) |
Current consumption | <25 mA (at 24 V DC) <50 mA (at 5 V DC) |
Output signals | sin, /sin, cos, /cos, index, /index |
Output voltage | 1 VPP ±10 % (at 0 ... 70 °C, 120 Ω teminal resistance) |
Output impedance | 0 Ω (RLoad >75 Ω) (short-circuit proof) |
Signal period | 1000 µm |
Offset voltage | 2.5 V, ±100 mV (sine/cosine mean to GND (10.5 ... 30 V DC)) UB/2 ±100 mV (sine/cosine mean to GND (5 V DC)) |
Phasing | 90°±1°, ±3° (20 kHz) (sin/cos) 45° sin/cos (reference signal is symmetric around the positive intersection point of the sin/cos signals (phase 45°)) |
Real-time requirement | speed-proportional signal output |
Type of connection | open cable end plug connector (7/8-pole) |
System data | |
Linearity deviation | ±2 µm (at TU = 20° C, reading distance 0.2 mm) |
Repeat accuracy | 1 µm |
Measuring range | ∞ |
Circumferential speed | ≤20 m/s (sin/cos) |
Travel speed | ≤20 m/s (sin/cos) |
Ambient conditions | |
Ambient temperature | -10 … 70 °C |
Storage temperature | -30 … 80 °C |
Relative humidity | 100 % (condensation admissible) |
EMC | EN 61000-6-2 (interference resistance / immission) EN 61000-6-4 (emitted interference / emission) |
Protection category | IP67 (EN 60529) |
Shock resistance | 500 m/s2, 11 ms (EN 60068-2-27) |
Vibration resistance | 200 m/s2, 50 Hz … 2 kHz (EN 60068-2-6) |