Description
  • Repeat accuracy max. ±1 μm
  • Status LED display
  • Works with MB100/1 magnetic tape

  • Works with MBR100 magnetic tape ring

  • Reading distance ≤0.4 mm
  • Signal period 1000 μm
  • Output circuit sin/cos 1 VSS
  • Robust metal housing
Technical data
Mechanical data
Housing zinc die-cast/aluminum (M design)
zinc die-cast (ZM design)
Sensor/band reading distance 0.1 … 0.4 mm (reference signal O, IA, ID)
0.1 … 0.2 mm (reference signal RB, RD)
Sensor/ring reading distance 0.1 … 0.4 mm (reference signal O, IA, ID)
0.1 … 0.2 mm (reference signal RB, RD)
Cable sheath PUR, suitable for drag-chain use (6, 8-wire ø5-0.4 mm)
Cable bending radius 5x cable diameter (static)
7.5x cable diameter (dynamic)
Service life of cable >5 million cycles (under the following test conditions:
travel range 4.5 m
travel  speed 3 m/s
acceleration 5 m/s2
ambient temperature 20 °C ±5 °C)
Electrical data
Operating voltage 10.5 … 30 V DC (reverse polarity protected)
5 V DC ±5 % (no reverse polarity protection)
Current consumption <25 mA (at 24 V DC)
<50 mA (at 5 V DC)
Output signals sin, /sin, cos, /cos, index, /index
Output voltage 1 VPP ±10 % (at 0 ... 70 °C, 120 Ω teminal resistance)
Output impedance 0 Ω (RLoad >75 Ω) (short-circuit proof)
Signal period 1000 µm
Offset voltage 2.5 V, ±100 mV (sine/cosine mean to GND (10.5 ... 30 V DC))
UB/2 ±100 mV (sine/cosine mean to GND (5 V DC))
Phasing 90°±1°, ±3° (20 kHz) (sin/cos)
45° sin/cos (reference signal is symmetric around the positive intersection point of the sin/cos signals (phase 45°))
Real-time requirement speed-proportional signal output
Type of connection open cable end
plug connector (7/8-pole)
System data
Linearity deviation ±2 µm (at TU = 20° C, reading distance 0.2 mm)
Repeat accuracy 1 µm
Measuring range
Circumferential speed ≤20 m/s (sin/cos)
Travel speed ≤20 m/s (sin/cos)
Ambient conditions
Ambient temperature -10 … 70 °C
Storage temperature -30 … 80 °C
Relative humidity 100 % (condensation admissible)
EMC EN 61000-6-2 (interference resistance / immission)
EN 61000-6-4 (emitted interference / emission)
Protection category IP67 (EN 60529)
Shock resistance 500 m/s2, 11 ms (EN 60068-2-27)
Vibration resistance 200 m/s2, 50 Hz … 2 kHz (EN 60068-2-6)