Description
High-resolution magnetic absolute sensor for use in dynamic processes
- Max. resolution 1 μm
- Repeat accuracy 2 μm
- System accuracy up to 10 μm
SSI, RS485, DRIVE-CLiQ output circuits
- Additional analog real-time signal output Sin/Cos 1 VSS for highly dynamic control (SSI/RS485)
- Signal period 1 mm
- Certified according to SIL2 (DRIVE-CLiQ) for safety applications
- Industry 4.0 ready
Technical data
Mechanical data | |
Housing | zinc die-cast |
Sensor/band reading distance | ≤0.3 mm (without masking tape on magnetic tape) |
Electrical data | |
Operating voltage | 4.5 … 30 V DC (reverse polarity protected (RS485, SSI)) 10 … 30 V DC (reverse polarity protected, SELV/PELV (DRIVE-CLiQ)) |
Power input | ≤1.2 W (RS485, SSI) ≤1.6 W (DRIVE-CLiQ) |
Temperature sensor input | external sensor, type KTY84 (DRIVE-CLiQ (12-pole plug connector)) |
SSI clock speed input | ≤750 kHz (caution: max. clock rate depends on cable length) |
Output voltage | 1 VPP (RS485, SSI) |
Period length of sin/cos output | 1000 µm (RS485, SSI) |
Interface | SSI, RS485, DRIVE-CLiQ |
Real-time requirement | speed-proportional signal output (sin/cos output (RS485, SSI)) |
Cycle time | <25 µs (RS485, SSI) <30 µs (DRIVE-CLiQ) |
Type of connection | M12 plug connector (A-coded) (12-pole, 1x pin (RS485, SSI, DRIVE-CLiQ with temperature sensor input)) M12 plug connector (A-coded) (8-pole, 1x pin (DRIVE-CLiQ)) |
System data | |
Pole length | 1 mm |
Resolution | 1 µm |
System accuracy | ±10 µm (at TU = 20 °C) |
Repeat accuracy | ≤2 µm (unidirectional) |
Measuring range | ≤4000 mm |
Travel speed | ≤2 m/s (static operation (RS485, SSI)) ≤10 m/s (dynamic operation (sin/cos) (RS485, SSI)) ≤5 m/s (DRIVE-CLiQ) |
Functional safety | SIL 2 according to EN 61508 (as well as EN 61800-5-2 category 3, PL d according to EN ISO 13849-1: 2008 (DRIVE-CLiQ)) |
Failure rate | 413 year(s) (at 40 °C (MTTFd), DRIVE-CLiQ) 3.82 x 10-9/h (at 40 °C (PFH), DRIVE-CLiQ) |
Error detection | 92.2 % (at 40 °C (DCavg), DRIVE-CLiQ) |
Safe position | <6 mm (DRIVE-CLiQ) |
Ambient conditions | |
Ambient temperature | -30 … 85 °C (RS485, SSI) -30 … 80 °C (DRIVE-CLiQ) |
Storage temperature | -40 … 85 °C |
Expansion coefficient | (11 ±1) x 10-6/K |
Relative humidity | 100 % (condensation admissible) |
EMC | EN 61000-6-2 (interference resistance / immission) EN 61000-6-4 (emitted interference / emission) |
Protection category | IP67 (EN 60529, mating connector mounted) |
Shock resistance | 500 m/s2, 11 ms (EN 60068-2-27) |
Vibration resistance | 100 m/s2, 5 … 150 Hz (EN 60068-2-6) |