« Back
Magnetic sensor MSK200/1

Magnetic sensor MSK200/1

PRODUCENT CODE: -
CATEGORY: Linear position transducers - Magnetic sensors - Magnetic sensors
Producer: SIKO GmbH
The product is available on request
At the moment, the product is not available in our warehouse.
After placing the order, we will notify you of the expected delivery date of the product.
Fast shipping
Free delivery
from 1000 PLN (net)
Do you have questions about the product?
Ask an experienced consultant:
+48 32 237 61 98 w. 117
rw@newtech.com.pl
Description
  • Max. resolution 0.4 μm
  • Works with MB200/1 magnetic tape, MR200 magnetic ring, MBR200 magnetic tape ring
  • Reading distance ≤1 mm

  • IP67 protection class
  • Optionally with reference point R or flexible reference marks FR
  • Interface LD
  • Interface RS485 with Panasonic or Yaskawa protocol
Technical data
Mechanical data
Housing green plastic (A design)
zinc die-cast (ZM design)
Sensor/band reading distance 0.1 … 1 mm (O, I reference signals)
0.1 … 0.5 mm (R reference signal)
0.4 … 0.5 mm (FR reference signal)
Sensor/ring reading distance 0.1 … 0.8 mm (O, I reference signals)
0.1 … 0.4 mm (R reference signal)
Cable sheath PUR suitable for drag-chain use (4-core ø 4.4-0.4  mm; 6, 8-core ø 5-0.4  mm)
Cable bending radius 5x cable diameter (static)
7.5x cable diameter (dynamic)
Service life of cable >5 million cycles (under the following test conditions:
travel range 4.5 m
travel  speed 3 m/s
acceleration 5 m/s2
ambient temperature 20 °C ±5 °C)
Electrical data
Operating voltage 24 V DC ±20 %
5 V DC ±5 %
Current consumption ≤100 mA (at 24 V DC)
≤30 mA (at 5 V DC)
Output signals A, /A, B, /B, I, /I, R, /R, FR, /FR
Latency 1.5 µs
Interface LD (RS422)
RS485/P (Panasonic) (Minas A5, A6)
RS485/Y (Yaskawa) (SIGMA 7)
Real-time requirement speed-proportional signal output
Type of connection open cable end
plug connector (7/8-pole)
D-Sub (9-pole)
System data
Resolution 0.0004, 0.0005, 0.001, 0.002, 0.004, 0.005, 0.01, 0.025 mm
Scaling factor 1250, 1000, 500, 250, 125, 100, 50, 20
Linearity deviation ±5 µm (at TU = 20° C)
Repeat accuracy ±1 increment(s)
Measuring range
Circumferential speed dependent on resolution and pulse interval (cf. LD table)
≤4.5 m/s (RS485/P, RS485/Y)
Travel speed dependent on resolution and pulse interval (cf. LD table)
≤4.5 m/s (RS485/P, RS485/Y)
Ambient conditions
Ambient temperature -10 … 70 °C
Storage temperature -30 … 80 °C
Relative humidity 100 % (condensation admissible)
Protection category IP67 (EN 60529)