Magnetic sensor MSK320R
PRODUCENT CODE: -
CATEGORY: Linear position transducers - Magnetic sensors - Magnetic sensors
Producer: SIKO GmbH
The product is available on request
At the moment, the product is not available in our warehouse.
After placing the order, we will notify you of the expected delivery date of the product.
At the moment, the product is not available in our warehouse.
After placing the order, we will notify you of the expected delivery date of the product.
Fast shipping
Free delivery
from 1000 PLN (net)
Free delivery
from 1000 PLN (net)
Do you have questions about the product?
Ask an experienced consultant:
Ask an experienced consultant:
Description
The MSK320R contains two sensor elements and two signal conditioners, therefore providing two independent output signals A1. A2. B1 and B2 as well as the associated inverted signals /A1. /A2 /B1 and /B2.
- Enhanced safety owing to independent output channels
- 2 magnetic sensors and 2 signal conditioners in one sensor head
- Works with MB320/1 magnetic tape, MRI01 or MR320 magnetic ring, MBR320 magnetic tape ring
- Reading distance ≤2 mm
- Repeat accuracy of ±1 increment
- extensive application temperature range of -40 … 85° C
- Cost advantage by installation of one MSK320R sensor instead of two MSK320 sensors
Technical data
Mechanical data | |
Housing | zinc die cast (ZM design) |
Sensor/band reading distance | 0.1 … 2 mm (reference signal O) |
Sensor/ring reading distance | 0.1 … 2 mm (reference signal O) |
Cable sheath | PUR drag chain-compatible (10-core, ø4.8 ±0.15 mm) |
Electrical data | |
Operating voltage | 4.5 … 30 V DC (reverse polarity protected) |
Current consumption | <20 mA (at 24 V DC, off-load) <75 mA (loaded) |
Output circuit | PP, LD (RS422) (PP only with 4.5 ... 30 V DC and LD only with 4.5 ... 6 V DC) |
Output signals | A1, /A1, B1, B/1, A2, A/2, B2, B/2 (quadrature signal) |
Output signal level high | >UB -2.5 V (PP) >2.5 V (LD) |
Output signal level low | <0.8 V (PP) <0.5 V (LD) |
Pulse width of reference signal | 1 increment(s) |
Real-time requirement | velocity-proportional signal output |
Type of connection | open cable end |
System data | |
Resolution | 0.8, 0.4, 0.2, 0.1, 0.05, 0.025, 0.0125 mm (each channel configurable) |
Scaling factor | 1, 2, 4, 8, 16, 32, 64 (each channel configurable) |
Linearity deviation | ±30 µm (at TU = 20° C, reading distance 1 mm) |
Repeat accuracy | ±1 increment(s) |
Measuring range | ∞ |
Circumferential speed | ≤25 m/s |
Travel speed | ≤25 m/s |
Ambient conditions | |
Ambient temperature | -40 … 85 °C |
Storage temperature | -40 … 85 °C |
Relative humidity | 100 % (condensation admissible) |
EMC | EN 61326-1 (immunity requirement of industrial applications, emission limit class B) |
Protection category | IP67 (EN 60529) |
Shock resistance | 500 m/s2, 11 ms (EN 60068-2-27) |
Vibration resistance | 100 m/s2, 5 … 150 Hz (EN 60068-2-6) |