FLI
• One Mechan safety switch input
• Monitored limited inch button input
• 2, 4 or 5 second versions
• LED and volt free contact indication
• 35mm DIN rail mounting
• 17.5 mm wide
The FLI extender module provides the option of using a limited inch button control (not supplied) to override one Mechan safety switch in an F Series safety system for a pre-set maximum time. Simple connection via a built in 6-way strap to the adjacent F Series module, the FLI has the input for 1 Mechan safety switch and connections for the limited inch button. When fitted correctly the button can override the Mechan switch, connected to the FLI, for up to the maximum time allowed. Releasing the button or reaching the maximum allowed time re-activates the switch.
Specyfikacja techniczna | |
Pobór mocy | na |
Przewód/złącze | Zaciski śrubowe |
Kodowanie | Electronic, Generic code |
Wejście | 1 Electronic Safety Switch + 2 Hand Override |
Wskazanie | Guard Status LED and Volt Free Contact |
Wymiary jednostki sterującej (mm) | 17.5 x 90 x 58mm |
Klasa IP | Obudowa IP30, zaciski IP20 |
Budowa | Grey PC-GF |
Montaż | 35mm szyna DIN |
Parametry środowiskowe | |
Temperatura robocza | 0°C do 45°C |
Temperatura przechowywania | -20°C do 60°C |
Dane dotyczące bezpieczeństwa | |
PL zgodnie z EN ISO 13849-1 | na |
SIL CL zgodnie z EN IEC 62061 | na |
PFHd zgodnie z EN IEC 62061 | na |
PFH | na |
B10d | na |
MTTFd | na |
TM | na |
DC | na |
SFF | na |
Notes | |
As part of an F Series system |